push button panel control<br />
Keep the selection key pressed (for example 1 <strong>ESPRESSO</strong><br />
coffee). The test is OK if what is shown on the display goes<br />
from 0 to 1.<br />
k .. indicates the push button code (see drawings on page<br />
25. Press ENTER to go to the next check.<br />
group microswitches control<br />
MIKRO GR.1 GR.2<br />
1 K27 K30<br />
2 K28 K31<br />
3 K29 K32<br />
Disconnect the microswitch wire (for example of microswitch<br />
1) and connect it to the central contact of the microswitch.<br />
The test is OK if what is shown on the display goes from 0 to<br />
1 or 1 to 0 depending on the position of the micro.<br />
Press ENTER to go to the next check<br />
grounds drawer control<br />
Open the coffee grounds drawer. The test is OK if the on the display appears:<br />
- 1 with grounds drawer closed<br />
- 0 with grounds drawer open<br />
Press ENTER to go to the next check.<br />
ispection door control<br />
The test is OK if the display shows:<br />
- 1 with door closed<br />
- 0 with door open<br />
Press ENTER to go to the next check.<br />
boiler sensors control<br />
Disconnect either the wire of the water level sensor or of the minimum<br />
level sensor. The test is positive if the following is displayed:<br />
- 1 wire connected to the sensor<br />
- 0 with wire disconnected from the sensor<br />
Press ENTER to go to the next check.<br />
keys control<br />
Put the key in its lock. The test is OK if the on the display appears:<br />
- 1 whit waiters key inserted<br />
- 0 whit waiters key disconnected<br />
Press ENTER to go to the next check.<br />
27<br />
english<br />
Technical manual<br />
TEST InPUT<br />
K 1 0 ---> 1<br />
3<br />
2<br />
TEST InPUT<br />
K 27 0 ---> 1<br />
TEST InPUT<br />
K 33 1 ---> 0<br />
TEST InPUT<br />
K 34 1 ---> 0<br />
TEST InPUT<br />
K 36 0 ---> 1<br />
TEST InPUT<br />
K 40 0 ---> 1<br />
1<br />