display<br />
piston motor gr 1 - 2<br />
blocked<br />
insufficient GR 1 - 2<br />
compression<br />
cause remedy<br />
1. Microswitch no. 1 is either faulty<br />
or disconnected<br />
2. Incorrect setting of cam no. 1<br />
3. Foreign body inside the dispensing<br />
unit<br />
4. Coffee residues around the piston<br />
head<br />
1. The motor transformer<br />
protection fuse (24V) has<br />
blown<br />
2. The motor power supply (24V)<br />
connection has been cut off<br />
3. Transformer failure or cables<br />
disconnected on the primary or<br />
secondary circuits<br />
4. The dispensing unit driver is<br />
broken<br />
49<br />
english<br />
1. Reconnect and/or<br />
change microswitch<br />
no.1 if necessary<br />
Technical manual<br />
2. Check correct setting of cam no. 1<br />
(see Chap.11)<br />
3. Remove the foreign body<br />
4. Remove the coffee from around the<br />
piston using the brushes supplied<br />
- Press the key<br />
- Switch the machine off and then on<br />
1. Replace the fuse<br />
2. - Verify the perfect fitting of the power<br />
supply cables (Red and Black) inside the<br />
socket and on the motor connections<br />
- See if the brushes inside the motor are<br />
worn<br />
- Verify that connector P10 is connected<br />
properly on the back of the mother board<br />
as well as all its cables<br />
3. Check that the green pilot light under the<br />
boiler cover is on.<br />
Green pilot light ON:<br />
- transformer and connections OK<br />
Green pilot light OFF:<br />
- transformer broken (replace)<br />
- connections interrupted (restore)<br />
4. Replace the DRIVER board<br />
TROUBLESHOOTING - chap.10