OPTIMOD MAINTENANCE 4-11<br />

Test Procedure for the Base I/O Module<br />

If you have an <strong>8685</strong> with the base I/O module (no HD-SDI), follow steps 4 through 9<br />

below.<br />

4. Test Digital I/O and Sync for Input/Output 1/2 (Lf/Rf).<br />

A) Recall the AUDIT3 Setup. This uses the 2.0 processing chain as a test tone generator<br />

to test the surround channels.<br />

B) Using a 75Ω BNC/BNC jumper cable, the <strong>8685</strong>’s OUTPUT 11/12 BNC connector to<br />

its INPUT 1/2 BNC connector and verify that the 1/2 indicator on the <strong>8685</strong>’s<br />

front panel turns yellow, indicating that the <strong>8685</strong>’s INPUT 1/2 AES3id receiver<br />

has locked to the signal emitted from OUTPUT 11/12.<br />

C) Connect the digital analyzer to the <strong>8685</strong>’s OUTPUT1/2 BNC connector and verify<br />

that the THD+N is below –100 dBfs and that the sample rate is 48 kHz, as<br />

locked to the input sample rate.<br />

D) AUDIT3 emits its test signal at a 48 kHz sample rate. To test 32 kHz, 44.1 kHz,<br />

88.2 kHz, and 96 kHz sample rates, recall AUDIT4, AUDIT5, AUDIT6, and AUDIT7 in<br />

turn. Use the AES3id analyzer to do the following for each sample rate:<br />

a) Measure the THD+N and verify that it is below –100 dBfs (0.001%).<br />

b) Listen to the AES3id analyzer’s decoded analog output and verify that the<br />

output sounds clean and glitch-free.<br />

c) Verify that the frequencies measured at the <strong>8685</strong>’s OUTPUT 1/2 follow the<br />

values in the chart below within given tolerances.<br />

Sample Rate Tolerance (PPM) Tolerance ( Hz)<br />

32.0 kHz 100 PPM ±3.20 Hz<br />

44.1 kHz 100 PPM ±4.41 Hz<br />

48.0 kHz 100 PPM ±4.80 Hz<br />

88.2 kHz 100 PPM ±8.82 Hz<br />

96.0 kHz 100 PPM ±9.60 Hz<br />

Table 4-4: Frequency Tolerance for Various Sample Rates<br />

5. Test Digital I/O and Sync for Input/Output 3/4 (C/LFE).<br />

Connect the <strong>8685</strong>’s OUTPUT 11/12 BNC connector to its INPUT 3/4 BNC connector,<br />

connect the analyzer to OUTPUT 3/4, and follow the procedure in step 4 by analogy.<br />

Use Setups AUDIT8 through AUDIT12.<br />

6. Test Digital I/O and Sync for Input/Output 5/6 (Ls/Rs).<br />

Connect the <strong>8685</strong>’s OUTPUT 11/12 BNC connector to its INPUT 5/6 BNC connector,<br />

connect the analyzer to OUTPUT 5/6, and follow the procedure in step 4 by analogy.<br />

Use Setups AUDIT13 through AUDIT17.