<strong>F9000N</strong> & F2004N Series Operating <strong>Manual</strong><br />

Section 6 : Point Type & Function Reference Rev. C- Oct. 11<br />

1. Point Menu<br />

Below is a list of functions which are found under the ENTER key. These functions are<br />

„point-type‟ functions. The values applied will occupy one memory address.<br />

1.1. Dispense Dot<br />

Registers the current XYZR location as a Dispense point for dispensing a dot.<br />

The dispense time and wait time must be set in a previous memory address by registering<br />

a Point Dispense Setup instruction with the SETUP key.<br />

The upward motion of the tip after dispensing can be controlled by registering a Dispense<br />

End Setup instruction and / or a Z Clearance instruction in a previous memory address.<br />

Dispense End Setup and Z Clearance instructions are registered using the SETUP key.<br />

See also Section 6:3.3 Point Dispense Setup, Section 6:3.4 Dispense End Setup and<br />

Section 6:3.5 Z Clearance.<br />

1.2. Line Start<br />

Registers the current XYZR location as a Line Start point for dispensing a line.<br />

The line speed must be set in a previous memory address by registering a Speed<br />

instruction using the SETUP key.<br />

Dispense delay times used at Line Start point can be controlled by registering a Line Dis.<br />

Setup instruction in a previous memory address. The Line Dis. Setup instruction is<br />

registered by pressing the SETUP key.<br />

See also Section 6:3.1 Line Speed and Section 6:3.2 Line Dispense Setup.<br />

- Page 62 -<br />