F9000N Manual - Fisnar.fr
F9000N Manual - Fisnar.fr
F9000N Manual - Fisnar.fr
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>F9000N</strong> & F2004N Series Operating <strong>Manual</strong><br />
Section 6 : Point Type & Function Reference Rev. C- Oct. 11<br />
1. Point Menu<br />
Below is a list of functions which are found under the ENTER key. These functions are<br />
„point-type‟ functions. The values applied will occupy one memory address.<br />
1.1. Dispense Dot<br />
Registers the current XYZR location as a Dispense point for dispensing a dot.<br />
The dispense time and wait time must be set in a previous memory address by registering<br />
a Point Dispense Setup instruction with the SETUP key.<br />
The upward motion of the tip after dispensing can be controlled by registering a Dispense<br />
End Setup instruction and / or a Z Clearance instruction in a previous memory address.<br />
Dispense End Setup and Z Clearance instructions are registered using the SETUP key.<br />
See also Section 6:3.3 Point Dispense Setup, Section 6:3.4 Dispense End Setup and<br />
Section 6:3.5 Z Clearance.<br />
1.2. Line Start<br />
Registers the current XYZR location as a Line Start point for dispensing a line.<br />
The line speed must be set in a previous memory address by registering a Speed<br />
instruction using the SETUP key.<br />
Dispense delay times used at Line Start point can be controlled by registering a Line Dis.<br />
Setup instruction in a previous memory address. The Line Dis. Setup instruction is<br />
registered by pressing the SETUP key.<br />
See also Section 6:3.1 Line Speed and Section 6:3.2 Line Dispense Setup.<br />
- Page 62 -<br />
© 2010 <strong>Fisnar</strong> Inc.