10.07.2015 Views

Extraction Plan - Peabody Energy

Extraction Plan - Peabody Energy

Extraction Plan - Peabody Energy

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Extraction</strong> <strong>Plan</strong> – North Wambo Underground Mine Longwalls 7 and 8Table 20Public Safety Management Issues Associated with the <strong>Extraction</strong> of Longwalls 7 and 8Issue Approved Impact Revised Impact Monitoring ManagementAgistee’saccessing theLongwalls 1 to 8area to managestock.Unauthorisedaccess to theLongwalls 1 to 8area (e.g. throughaccess from theright of way acrossWCPL-ownedland*, looking forfirewood orhunting).Ausgrid personnelservicingpowerlines withinthe Longwalls 7and 8 ApplicationArea.Members of thepublic visiting theWHC.Subsidenceimpacts, which maybe considered topose a safetyhazard, currentlyapproved include:• surfacecracking; 1• erosion; 1 and• ponding. 1• Impacts resultingfrom the extractionof Longwalls 7 and8 will be consistentwith thosepresented in theEIS and the NorthWambo SEE.• Monitoring ofsubsidence inaccordance withthe SubsidenceMonitoring Program(Appendix H).• Visual observationsof fences.• Visual observationsof warning signs(e.g. legibility).• Restricted access (i.e. the general public are not allowedon WCPL-owned land used for mining purposes).Permanent signage located at the entrance toWCPL-owned land will be maintained.• Notification to agistees of areas of longwall mining andactive subsidence, and exclusion of agistment grazing fromareas where surface cracking presents a reasonable risk topeople and/or livestock.• Posting of warning signs at suitable locations on propertyboundaries, fences and access tracks, including the right ofway across WCPL-owned land*. The signs will indicate thatunderground mining (with surface subsidence) is beingundertaken on WCPL-owned land and will prohibit entry byunauthorised persons.• Maintenance of warning signs.• Management of surface cracking and areas of subsidencetroughs in accordance with the LMP (Table 13).• All safety incidents will be handled in accordance with theH&SMS.• Repair of fences in accordance with the LMP.• Review of warning sign placement and removal if no longerrequired.Members of theRural Fire Serviceaccessing theLongwalls 7 and 8Application Area.1 After the EIS (WCPL, 2003).* A right of way in favour of two private properties (the route of which may be varied on reasonable notice) across WCPL-owned land is situated in the vicinity (but outside) of the ApplicationAreas for Longwalls 1 to 8.EP/SMP LW7-8 Rev B December 2012 Page 47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!