5.E+054.E+054.E+05Moment (kN-m)3.E+053.E+052.E+052.E+051.E+05M =3×10 5 kN-mxM xy = 250000 kN-mΦ xy = 0.04×10 -2 rad/mM xu = 414000 kN-mΦ xu = 0.48×10 -2 rad/m5.E+040.E+000.0 0.5 1.0 1.5 2.0 2.5 3.0Curvature (10 -2 rad/m)Figure 6.15 Hollow section capacity about strong axis bending3.E+053.E+05Moment (kN-m)2.E+052.E+051.E+05M yy = 159000 kN-mΦ yy = 0.08×10 -2 rad/mM yu = 243000 kN-mΦ yu = 1.12×10 -2 rad/m5.E+040.E+000.0 1.0 2.0 3.0 4.0 5.0 6.0Curvature (10 -2 rad/m)Figure 6.16 Hollow section capacity about weak axis bendingAfter <strong>the</strong> bending moment demands have been determined from <strong>the</strong> FE model <strong>of</strong> <strong>the</strong>bridge, <strong>the</strong> capacity over demand ratio <strong>of</strong> each column can be evaluated. The ratios <strong>of</strong> <strong>the</strong>bending capacity to <strong>the</strong> maximum moment are listed in Table 6.4, in which M x and M yare <strong>the</strong> bending moments about x and y axis, respectively, under <strong>the</strong> design earthquake,and M xu and M yu are <strong>the</strong>ir corresponding capacities. Since <strong>the</strong> entire structure is88