FEATURE MenuParameter Choices DescriptionREGULATREGWORDNTEPCANADAINDUSTNONEOIMLGROSSBRUTTORegulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.• OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greaterthan zero. NONE allows tares to be acquired at any weight value.• OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight isat no load. NONE allows tares to be cleared at any weight value.• NTEP and OIML modes allow a new tare to be acquired even if a tare is alreadypresent. In CANADA mode, the previous tare must be cleared before a new tare can beacquired.• NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or netmode as long as the current weight is within the specified ZRANGE. In OIML mode, thescale must be in gross mode before it can be zeroed; pressing the ZERO key in netmode clears the tare.• INDUST provides a set of subparameters to allow customization of tare, clear, and printfunctions in non-legal-for-trade scale installations. See Level 4 parameter descriptionsin Table 3-9 on page 47.The value specified for this parameter affects the function of the front panel TARE and ZEROkeys. See Section 10.2 on page 109 for a complete description of TARE and ZERO keyfunctions for each of the regulatory modes.Sets the term displayed when weighing in gross mode. Selecting BRUTTO replaces theGross annunciator with Brutto.CONTACT — Allows specification of contact information for use in iQUBE 2 alert messages. See Level 3submenu descriptions in Table 3-8 on page 46.LOCALEOFFONLATUDE 450–90ELEVAT 345±0–9999IMAGE NEGATIVEPOSITIVELANGUAGELevel 3 submenusDATEFMTDATESEPTIMEFMTTIMESEPENGLISHlanguageMMDDYYYYDDMMYYYYYYYYMMDDYYYYDDMMSLASHDASHSEMI12HOUR24HOURCOLONCOMMALocale. Set this parameter ON to enable the LATUDE and ELEVAT parameters. Specifyinglatitude and elevation of the scale site provides compensation for gravitational effects.Attached scales must be recalibrated after changing this parameter from OFF to ON.NOTE: Gravitational compensation settings do not affect iQUBE 2 scales.Latitude. Specify the latitude of the scale site in degrees. This parameter is shown only ifLOCALE=ON.Elevation. Specify the elevation of the scale site in meters. Valid values are –9999 through9999. This parameter is shown only if LOCALE=ON.Specifies whether the indicator display is presented as blue-on-white or white-on-blue. The default value, NEGATIVE, shows the standard blue-on-white image when using thestock LCD display; the optional outdoor display shows white-on-blue. When using theoutdoor display, set this value to POSITIVE to show the standard, blue-on-white displayimage, then use the LCD contrast potentiometer to adjust for optimal viewing.Specifies the language and character set used for <strong>920i</strong> prompts and printing.Specifies the format used to display or print the date.Specifies the date separator character.Specifies the format used to display or print the time.Specifies the time separator character.Table 3-7. FEATURE Menu Parameters (Continued)Configuration 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!