11.07.2015 Views

ΑΡΘΡΟ ΣΥΝΤΑΞΗΣ - Το Βήμα του Ασκληπιού

ΑΡΘΡΟ ΣΥΝΤΑΞΗΣ - Το Βήμα του Ασκληπιού

ΑΡΘΡΟ ΣΥΝΤΑΞΗΣ - Το Βήμα του Ασκληπιού

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ΤΟ ΒΗΜΑ ΤΟΥ ΑΣΚΛΗΠΙΟΥ Copyrigh t © 2008Τόμο ς 7 ος , Τεύχος 4 ο , Οκτώβριος – Δεκέμβριος 2008intensive care patients. Crit Care Medflow‐resistive work load due to1997; 25:1707‐1712humidifying devices. Chest 1990;36 Branson RD, Davis K, Jr., Campbell RS,97:600‐604Johnson DJ, Porembka DT. 41 Girault C, Breton L, Richard JC, Tamion F,Humidification in the intensive care unit.Vandelet P, Aboab J, et al. MechanicalProspective study of a new protocoleffects of airway humidification devicesutilizing heated humidification and ain difficult to wean patients. Crit Carehygroscopic condenser humidifier. ChestMed 2003; 31:1306‐13111993; 104:1800‐180542 Buckley PM. Increase in resistance of inline37 Kollef MH, Shapiro SD, Boyd V, Silver P,breathing filters in humidified air.Von Harz B, Trovillion E, et al. ABr J Anaesth 1984; 56:637‐643randomized clinical trial comparing an 43 Prasad KK, Chen L. Complications relatedextended‐use hygroscopic condenserto the use of a heat and moisturehumidifier with heated‐waterexchanger. Anesthesiology 1990; 72:958humidification in mechanically 44 McEwan AI, Dowell L, Karis JH. Bilateralventilated patients. Chest 1998;tension pneumothorax caused by a113:759‐767blocked bacterial filter in an anesthesia38 Misset B, Escudier B, Rivara D, Leclercqbreathing circuit. Anesth Analg 1993;B, Nitenberg G. Heat and moisture76:440‐442exchanger vs heated humidifier during 45 Lellouche F, Qader S, Taille S, Lyazidi A,long‐term mechanical ventilation. ABrochard L. Under‐humidification andprospective randomized study. Chestover‐humidification during moderate1991; 100:160‐163induced hypothermia with usual devices.39 Lorente L, Lecuona M, Galvan R, RamosIntensive Care Med 2006; 32:1014‐1021MJ, Mora ML, Sierra A. Periodically 46 Wilkes AR. The effect of gas flow on thechanging ventilator circuits is notfiltration performance of breathingnecessary to prevent ventilatorassociatedsystem filters. Anaesthesia 2004;pneumonia when a heat and59:278‐282moisture exchanger is used. Infect 47 Iotti GA, Olivei MC, Palo A, Galbusera C,Control Hosp Epidemiol 2004; 25:1077‐Veronesi R, Comelli A, et al. Unfavorable1082mechanical effects of heat and moisture40 Nishimura M, Nishijima MK, Okada T,exchangers in ventilated patients.Taenaka N, Yoshiya I. Comparison ofIntensive Care Med 1997; 23:399‐405vima‐asklipiou.gr Σελίδα 305

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!