11.07.2015 Views

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ATEX</strong> Compliant ISO Cylinder/Standard:Double ActingSeries 55-CP95ø32, ø40, ø50, ø63, ø80, ø100How to Order55-CP95SDB 32100 WPiston rod typeSKStandardNon-rotatingModel SelectionExecutionStandard TypeNon-rotatinpiston rod<strong>ATEX</strong> category 2BLFGCDBuilt-in magnet-DMountingBasic/Without bracketAxial footFront flangeRear flangeSingle rear clevisDouble rear clevisModel55-CP95 SB55-CP95 SDB55-CP95 KB55-CP95KDBNoneBuilt in magnet3240506380100Bore size32mm40mm50mm63mm80mm100mmRod Specifications-WStroke (mm)Refer to standard stroke tablefollowing pageAdjustableStroke EndCushioningPiston RodOptionsStandardHard ChromeNote 3)Note 3)Hard chromed rod as standardDouble rodWW = Double RodOptionsStandardNote1) 55-C95 can be used in zones 1 and 21 and in zones 2 and 22.Note2) If the 55-C95 cylinder is used with <strong>SMC</strong> category 3 type auto switch, then the 55-C95 cylinder can only be used in zones 2 and 22 and not zones 1 and 21.Note3) Piston rod material is stainless steel.For 55-CP95When using an Auto switch, select the appropriate switch from the following table and order it separately.Applicable auto switch specificationsAuto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10°C ≤ Ta ≤ +60°C IP67)For detailed specifications on the D-Z73, Z80, Y7P, and Y7PV, please refer to the relevant pages in Best Pneumatics.(Note: Reed auto switches for AC 100V and DC 100V are not within the specification.)10TypeReedauto switchSolid stateauto switch• Lead wire lengthModel No.D-Z73-588D-Z80-588D-Y7P-588D-Y7PV-588Electrical entryGrommet(in-line)Grommet(in-line)Grommet(Perpendicular)0.5m --- Nil (e.g.) D-Z73-5883 m --- L (e.g.) D-Z73L-5885 m --- Z (e.g.) D-Z73Z-588IndicatorYesNoYesWiring(Output)2-wiring3-wiring(PNP)Note 2) When mounting an auto switch on a 55- series (Category 2) Model,the <strong>ATEX</strong> category of the auto switch cylinder changes to Category 3,which is the same category as the auto switch.24VDC24V or less24VLoad voltage12V48V5V,12VNote 1)AC0.5(—)Lead wire ∗ (m)3(L)5(Z)IC circuitIC circuitApplicableloadRelayPLCsolid state auto switch is available after receiving an order.When ordering a direct mounting type auto switch,also order a mounting bracket from the following listat the same time.Auto switch mounting bracket/ Part no. (Direct mounting type)Auto switchModelD-Z73-588D-Z80-588D-Y7P-588D-Y7PV-58848V or lessTube I.D. (mm)32,40,50,63,80,100BMP1-032

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!