Decentralised Serial WiringSeries 56-EX250II 3GD EEx nA II T5 X 5°C ≤ Ta ≤ 45°C IP67For more details, other specifications,dimensions, see the specific catalogue.How to OrderInput blockSI unit<strong>ATEX</strong> category 356 -EX250 S PR1X42Communication protocolPR1 PROFIBUS-DPSI Unit SpecificationsHow to OrderInput block<strong>ATEX</strong> category 356 -2EX250 IE 2Block typeM12 connector, 4 inputsModelApplicable PLC/CommunicationprotocolCommunication speedOutputspecificationsInputspecificationsCurrent consumptionProtection structureWeight (g)X43Output pointOutput styleConnectionloadPower supply for blockResidual voltageInput pointInput styleConnection blockPower supply for blockCurrent supply for blockInput Block Specifications56-EX250-SPR1-X42PROFIBUS-DP(9.6/19.2/45.45/93.75/187.5/500 kbit/sec), (1.5/3/6/12 Mbit/sec)Max. 32 pointsP-ch MOS-FET open drain typeSolenoid valve with protection circuit for 24 VDCand 1.5 W or less surge voltage (made by <strong>SMC</strong>)24 VDC + 10%/–5%0.3 VDC or lessMax. 32 pointsTTL56-EX250-IE2-X4324 VDC ± 20%Max. 1 A0.1A or less (inside o SI unit)IP67250132ModelApplicable sensorRated voltage VeLogical ''1''input voltage VHLogical ''0''input voltage VLLogical ''1''input current IHLogical ''0''input current IL2 wire type sensor connectionInput delay timeSensor supply currentProtection structureWeight (g)56-EX250-IE2-X43Current source type (PNP output)Current sink type (NPN output) / converted by a switch24 VDC(Max. 1V of voltage effect against SI unit supply voltage)+11 to 30 VDC-3 to +5 VDC8 mA Min.2.5 mA Max.Possible3 m sec. Typ.Maximum 30 mA/SensorIP6790 g