11.07.2015 Views

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Series 52-SYSpecificationsSafety InstructionsFor more details, other specifications,dimensions, see the specific catalogueSeriesAmbient and fluid Temperature class T6temperature Temperature class T4, T5Coil temperature riseBarrier input voltage (non hazardous area)Solenoid valve input voltage (hazardous area)Intrinsically safeGas groupElectrical entryL typeT typeplug connectorterminal box52-SY5000 52-SY7000 52-SY900045°C50°C40°C or less (at rated)24VDC (system rated voltage) at 1.1W12VDC at 0.52WiaIIBIP30 (LL type : IP40)IP65Note1) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. Thetest were performed one time each in the axial and right angle directions of the main valve andarmature, in both energised and de-energised states (Valve in the initial stage).Vibration resistance: No malfunction ocurred in a one-sweep test between 8.3 and 2000Hz. The testwas performed for both energised and de-energised states in the axial and right angle directions of themain valve and armature (valve in the initial stage).1) This product is not suitable for Zone 0. The suitable zones are Zones 1 and 2.2) <strong>SMC</strong>-TAS and TAU Series, antistatic tubing, is available if required.3) the solenoid valve has polarity (+ -). Confirm the correct polarity by referring to thecolour of the lead wires. If the polarity is reversed, the barrier maybe damaged.4) Confirm that the solenoid input voltage at the lead wires is DC 10.8V (min).5) The product must be connected to a certified barrier or certified intrinsically safe circuitwith the follow maximum Values:Ui= 28Vli= 225mA (resistively limited)Pi= 1WCi= 0.nFLi= 0 nHNote) The valve is not supplied with barrier.Response timeConfiguration2-position single2-position double3-position52-SY500026 or less22 or less38 or lessResponse time (ms) (0.5MPa)52-SY700038 or less30 or less56 or less52-SY900050 or less50 or less70 or lessNote1) According to dynamic performance test JIS B8375-1981.Note2) Response time when barriers were combined with a valve.System A: Valve + Z728.H (Pepperl + Fuchs)B: Valve + MTL728P+C: Valve + MTL7128P+E: Valve + KFD2-SD-Ex1.17 (Pepperl + Fuchs)Note3) When system D is used, the ON time is delayed 17ms more than response time in table.System D: Valve + MTL5021Manifold specifications for 20 typeModelApplicable valveManifold style1 (SUP)/ 3/5 (EXH)Valve stations4/2 (A/B) LocationPort size 1,3,5 (P,EA,EB) PortSS5Y5-2052-SY5*20SS5Y7-2052-SY7*20Single base/ B mountingCommon SUP/ Common EXH2 to 20 (1)Valve1/44,2 (A,B) Port 1/81/4C4 (One-touch fittings for ø4mm)C8 (One-touch fittings for ø8mm)C6 (One-touch fittings for ø6mm)C10 (One-touch fittings for ø10mm)C8 (One-touch fittings for ø8mm)Manifold base weight W (g) n: Station W=36n+64W=43n+64Note1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port onboth sides and exhaust from EA/EB port on both side.Note2) 52-SY9*20 valve are not available with manifold as standard. Please contact <strong>SMC</strong> if you require it:Note3) 52-SY series are not available with resin type manifold (23 type, 20P type and 45 type).Manifold specifications for 41 and 42 typeModelSS5Y5-41 SS5Y5-42 SS5Y7-42Applicable valveManifold style52-SY5*40Single base/ B mounting52-SY7*401 (SUP)/ 3/5 (EXH)Valve stationsCommon SUP/ Common EXH2 to 20 (1)4/2 (A/B)Porting spec.LocationDirectionBaseSidePort size 1,3,5 (P,EA,EB) Port1/4 1/44,2 (A,B) Port1/81/41/4C6 (One-touch fittings for ø6mm) C6 (One-touch fittings for ø6mm) C10 (One-touch fittingsC8 (One-touch fittings for ø8mm) C8 (One-touch fittings for ø8mm) for ø10mm)Manifold base weight W (g) n: Station W=61n+101 W=79n+127 W=100n+151Note1) For more than 10 stations (more than 5 stations in case of SS5Y7), supply pressure to P port onboth sides and exhaust from EA/EB port on both side.Note2) 52-SY9*40 valve are not available with manifold as standard. Please contact <strong>SMC</strong> if you require it:Note3) 52-SY series are not available with resin type manifold (23 type, 20P type and 45 type).74Manifold specifications for 20 typePort sizeFlow characteristicsModel 1,5,3 4,2 1 > 4/2 (P>A/B) 4/2 > 5/3 (A/B > EA/EB)SS5Y5-20SS5Y7-20(P,EA,EB)1/41/4(A,B)C8C10c[dm 3 /(s.bar)]1.903.60b0.280.93Cv0.483.60c[dm 3 /(s.bar)]2.200.93b0.200.27Cv0.530.88Note) Values for 5 stations manifold with a 2 position single type valve.Manifold specifications for 41 and 42 typePort sizeFlow characteristicsModel 1,5,3 4,2 1 > 4/2 (P>A/B) 4/2 > 5/3 (A/B > EA/EB)SS5Y5-41SS5Y5-42SS5Y7-42(P,EA,EB)1/41/41/4(A,B)C8C8C10c[dm 3 /(s.bar)]1.801.903.00b0.230.200.25Cv0.440.460.75c[dm 3 /(s.bar)]1.901.903.00b0.160.120.12Cv0.450.430.66Note) Values for 5 stations manifold with a 2 position single type valve.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!