11.07.2015 Views

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5 Port Solenoid ValveSeries 56-SVII 3GD EEx nA II T5X T90° IP67For more details, other specifications,dimensions, see the specific catalogueApplicable to multi-connector>Manifold numbering system (Base piping type/ Tie rod base)56 - SS5VHow to Order1 W 10 N CD 06 U R C6<strong>ATEX</strong>category 31234Series56-SV100056-SV200056-SV300056-SV4000IP67 specificationPosition of P, E portUDBU side (4 to 10 stations)D side (4 to 10 stations)Both sides (4 to 10 stations)SUP/EXH blockassembly specificationNilRInternal pilot specificationExternal pilot specificationNil12VVoltage specification24VDC12VDC* Please pay attention to the polaritybecause a diode for protectingagainst miswiring is not incorporatedin the 12VDC version.Manifold base common specificationNilN04060810040608104 stations6 stations8 stations10 stations4 stations6 stations8 stations10 stations+COM-COMManifold stationDouble wiring Note1)Specified layoutNote2)Only the manifold stations above are available.When a valve number does not correspond to a manifold station,use a blanking plate to match both numbers.Note1) Double wiring specification: single, double, 3-position, and4-position solenoid valve can be used for all manifold station.When using a single solenoid, some control signals will not becounted. Therefore, specify the signal layout at the time an orderis placed.Note2) Layout specification:Please use the Manifold Specification Sheet to provide wiring.(The double solenoid valve and 3-position or 4-position solenoidvalve are not available when single wiring is specified. Please notethis.)A, B port size (mm)SymbolC3C4C6C4C6C8C6C8C10C8C10C12020302F03FMA & B portø3.2 One-touch fittingø4 One-touch fittingø6 One-touch fittingø4 One-touch fittingø6 One-touch fittingø8 One-touch fittingø6 One-touch fittingø8 One-touch fittingø10 One-touch fittingø8 One-touch fittingø10 One-touch fittingø12 One-touch fittingRc 1/4Rc 3/8G 1/4G 3/8Mixture of A and B portsA, B port size (inch)SymbolN1N3N7N3N7N9N7N9N11N9N1102N03N02T03TMA & B portø1/8" One-touch fittingø5/32" One-touch fittingø1/4" One-touch fittingø5/32" One-touch fittingø1/4" One-touch fittingø5/16" One-touch fittingø1/4" One-touch fittingø5/16" One-touch fittingø3/8" One-touch fittingø5/16" One-touch fittingø3/8" One-touch fittingNPT 1/4NPT 3/8NPTF 1/4NPTF 3/8Mixture of A and B portsP & E portø8 One-touchfittingø10 One-touchfittingø12 One-touchfittingø12 One-touchfittingRc 3/8G 3/8P & E portø5/16" One-touchfittingø3/8" One-touchfittingø3/8" One-touchfittingø3/8" One-touchfittingNPT 3/8NPTF 3/8Series56-SV1000series56-SV2000series56-SV3000series56-SV4000seriesSeries56-SV1000series56-SV2000series56-SV3000series56-SV4000seriesNote 1: Please complete the Manifold Specification Sheet when specifying themixture specification (M).Note2: For the external pilot specification (R), the X and PE port size are as follows:- ø4mm or ø5/32" for the 56-SV1000 and 56-SV2000 series- ø6mm or ø1/4" for the 56-SV3000 and 56-SV4000 series96

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!