11.07.2015 Views

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

ATEX compliant - SMC ETech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ATEX</strong> CompliantMechanically Jointed Rodless CylinderSe ries 55-MY1MSlide Bearing Type/ø16, ø20, ø25, ø32, ø40, ø50, ø63Standard strokesBore sizeStandard stroke (mm)(mm)16100, 200, 300, 400, 500, 600, 70020, 25, 32, 40 800, 900, 1000, 1200, 1400, 160050, 631800, 2000SymbolHow to OrderSlide BearingGuide Type 55-MY1M 25 300<strong>ATEX</strong> category 2SpecificationsBore size (mm)FluidActionOperating pressure rangeProof pressureAmbient and fluid temperatureCushionLubricationStroke length toleranceSlide bearingguide typeBore size1620253240506316mm20mm25mm32mm40mm50mm63mmPipingSymbol-TNTFStrokeRefer to thestandard stroketable below.TypeM threadRcNPTGBore sizeø16~ø20ø25~ø6316 20 25 32 40 50 63<strong>ATEX</strong> category 1) 75°C (T6) Ta 5 to 40°CII 2Gc95°C (T5) Ta 40 to 60°C1000 or less +1.81001 to 3000 +2.800-GAirDouble acting0.15 to 0.8MPa1.2MPa5 to 60°CAir cushionNon-lubePiping2700 or less +1.8 , 2701 to 5000 + 2.80 0Standard typeCentralized piping typePortsizeFront/Side portsM5 x 0.8Rc, NPT, G1/8Rc, NPT, G1/4Rc, NPT, G3/8Note) All other specifications(dimensions, drawings, etc.)are the same as the non <strong>ATEX</strong> type.Operating piston speed100 to 1000 mm/sNote 1) This cylinder can be used in zones 1 and 2.If the cylinder is used with <strong>SMC</strong> category 3 type auto switch, then thecylinder can only be used in zone 2 and not in zone 1.For 55-MY1MWhen using an Auto switch, select the appropriate switch from the following table and order it separately.Applicable auto switch specificationsAuto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10°C ≤ Ta ≤ +60°C IP67)For detailed specifications on the D-A93(V), A90(V), Z73, Z80, M9P(V) and Y7PV, please refer to the relevant pages in Best Pneumatics.(Note: Reed auto switches for AC 100V and DC 100V are not within the specification. Also for D-M9P(V) type, see D-F9P(V) type specifications.)TypeReedauto switchSolid stateauto switchø16 to ø20D-A93V-588D-A90V-588D-A93-588D-A90-588D-M9PV-588D-M9P-588Model No.ø25 to ø63D-Z73-588D-Z80-588D-Y7PV-588D-Y7P-588Electrical entryGrommet(Perpendicular entry)IndicatorYesWiring(Output)24VLoad voltageDC12VACNo24V or less2-wiring48V 48V or lessGrommet(In-line entry)GrommetYesNo24V24V or less12V48V 48V or less(Perpendicular entry)Yes 3-wiringGrommet (PNP)(In-line entry)24V 5V, 12V• Lead wire length 0.5m --- Nil (e.g.) D-A93-5883 m --- L (e.g.) D-A93L-5885 m --- Z (e.g.) D-A93Z-588Note 2) When mounting an auto switch on a 55- series (Category 2) Model,the <strong>ATEX</strong> category of the auto switch cylinder changes to Category 3,which is the same category as the auto switch.Note 1)0.5(—)Lead wire ∗ (m)3(L)5(Z)IC circuitIC circuitIC circuitApplicableloadRelayPLCsolid state auto switch is available after receiving an order.21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!