5. PARAMETER SETUP(1) Item A : IndicationThese items are for the indication of flowrate and total.Item Name R / W Data Range UnitA00A10A20DISPLAYFLOW RATE(%)FLOW RATERR0.0 to 110.00.0 to 65535A30 TOTALR 0 to 999999(Indicate only within Temperature sensor)A40 TEMP(%)(*1) R 0.0 to 110.0(Indicate only for Temperature sensor)A41 TEMPERATURE(*1) R –999.9 to 999.9A60 SELF CHECK R GOODERRORFU : Flow unit(*1): Only for Option Code /MV%FU+C40FU%D20Decimalpoint10 to 50 to 511RemarkMenu A (Display)Flow rateFlow rate (in engineering unit)Totalized valueTemperature Values (%)Temperature ValuesSelf-diagnostic messageInitialvalueDisp. U / DT050302.EPS(2) Item B : Easy SettingThese items are for the principal items to operate digitalYEWFLO.A value in “( )” is the data corresponding to the indicator.Item Name R / W Data Range UnitDecimalpointB00B10B15EASY SETUPFLOW SPANDAMPINGWW0.00001 to 320000 to 99FU + C40sec0 to 50B20 CONTACT OUT W OFF (0)SCALED PULSE (1)UNSCALED PULSE (2)FREQUENCY (3)ALARM (4)FLOW SW(LOW:ON) (5)FLOW SW(LOW:OFF) (6)(Indicate and Set only for B20 : SCALED PULSE, UNSCALED PULSE)B21 PULSE RATE W 0.00001 to 32000 FU / P 0 to 5(Indicate and Set only for B20 :FREQUENCY)B22 FREQ AT 100% W 0 to 10000PPS 0(Indicate and Set only for B20 :FLOW SW (ON), FLOW SW (OFF))B23 SET LEVEL W 0.00001 to 32000 FU +C40 0 to 5B30 UPPER DISP W FLOW RATE (%)FLOW RATE(0)(1)TEMP(%)(*1)B31 LOWER DISP W BLANKTOTAL(0)(1)TEMP(*1)B40 TOTAL START W STOPSTART(0)(1)B45B47TOTAL RATETOTAL RESETWW0.00001 to 32000NOT EXECUTEEXECUTE(0)(0)(1)FU / P 0 to 5(Indicate and Set only for Option code /MV)B50 A / OUT SELECT W FLOWTEMP(0)(1)(Indicate and Set only for B50: TEMP)B51B52TEMP 0%TEMP 100%WW-999.9 to 999.9-999.9 to 999.9D20D2011B60 SELF CHECK R GOODERRORRemarkMenu BFlow SpanDamping TimeContact Output TypePulse Output RatePulse Output Rate at sec / 100%Flow Switch (Actual Flow rate)Selection of Upper DisplaySelection of Lower DisplayStart / Stop of Totalizer(1) (1)Total RateTotalizer ResetSelection of Analog OutputSet Temperature Value at 0%Set Temperature Value at 100%Self-diagnostic messageInitialvalue104(0)1.010000(0)(0)(0)1.0(0)(0)-40250Disp. U / DD LD LD LD LD LD LD LD LD LD LD LD LD LD LFU : Flow unit(*1) : Only for Option Code /MVT050303.EPS5-2 <strong>IM</strong> <strong>01F06A00</strong>-<strong>01EN</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!