5. PARAMETER SETUP(5) Item E (METER SETUP)These items are for detector set up that has already been setbefore shipment.A value in “( )” is the data corresponding to indicator.[E10:NOMINAL SIZE] Nominal size of thedetectorSelect the nominal size of the flowmeter, from “15mm(0),25mm(1), 40mm(2), 50mm(3), 80mm(4), 100mm(5),150mm(6), 200mm(7), 250mm(8), 300mm(9)”[E20:BODY TYPE] Body type for the detectorSelect body type for detector from standard or high pressure.Standard(0) : Standard typeHigh Pressure (1) : High Pressure type (tokuchu)Low Flow Unit (1) (2) : Reduced Bore type (option : /R1)Low Flow Unit (2) (3) : Reduced Bore type (option : /R2)NOTEParameter setting for the Reduced Bore type,Select Low Flow Unit (1) or (2) and set. Setnominal size of the model code to E10:NOMINAL SIZE.[E30:SENSOR TYPE] Sensor type for thedetectorSelect sensor type for the detector from standard or HT/LT[E40:K-FACTOR UNIT],Select this unit from p/l, p/USgal, p/UKgal.<strong>IM</strong>PORTANTK-FACTOR is the eigenvalue of each detector.Please keep the factory preset value.NEVER REWRITE IT.(Unless the replacement of the remote type detector.)[E41:K-FACTOR]The flowmeter data plate includes a K-factor (KM) at 15°Cfor the combined detector.[E50:DETECTOR NO.] Detector number offlowmeterSet the serial number using 16 alphanumeric characters of thedetector combined converter.(6) ltem F (Thermometer)These items are for setting of thermometer and availablewhen build in thermometer type (Option code: /MV).[F10: Function] Thermometer functionSelect the thermometer function.Monitor only(0):Saturated Steam:Superheat Steam:Only temperature measurement.Mass Flow rate is calculated from densityvalues by temperature measurementusing saturated steam table.Mass Flow rate is calculated from densityvalues by temperature measured by usingsteam table. In order to measuresuperheat steam. It is necessary to makeconstant pressure value.GAS: STD/Normal: Volumetric flow rate at standardcondition is calculated by using Pressure-Temperature correction. It is necessary tomale constant pressure value.Liquid: Mass:Mass flow rate is calculated by using thedensity change values depend ontemperature values by which thesecondary order function is used.The following item should be done in case ofwhich F10 is Saturated steam[F12 MASS UNlT] Mass flow unitSelect mass rate unit from kg(0), t(1), lb(2), k lb(3).The following items should be done in case ofwhich F10 is Superheat steam[F14 PRESS UNIT] Pressure unitSelect pressure unit from MPa abs(0), kPa abs(1), bar abs(2),kg/cm 2 a(3), psia(4).[F15 PRESS f] Pressure valueSet absolute pressure values at operating condition.[F16 MASS UNIT] Mass flow unitSelect mass flow unit from kg(0), t(1), lb(2), k lb(3).The following items should be done in case of which F10 isGAS: STD/Normal[F18 TEMP UNIT] Temperature unitSelect temperature unit from deg C(0), deg F (1).[F19 TEMP b] Temperature bSet temperature value at normal/standard condition.5-13 <strong>IM</strong> <strong>01F06A00</strong>-<strong>01EN</strong>
5. PARAMETER SETUP[F20 PRESS UNIT] Pressure unitSelect pressure unit from MPa abs(0), kPa abs(1), bar abs(2),kg/cm 2 a(3), psia(4).[F21 PRESS f] Pressure value fSet absolute pressure values at operating condition.[F22 PRESS b] Pressure value bSet absolute pressure values at normal/standard Condition.[F23 DAVIATION] Daviation factorSet the daviation factor.[F24 STD/NOR UNIT] Standard/Normal unitSelect Volumetric unit at standard/normal condition FromNm3(0), k Nm3(1), M Nm3(2), Nl(3), Sm3(4)k Sm3(5), M Sm3(6), Sl(7), scf(8), k scf(9), M scf(10)N: NormalS: StandardThe following item should be done in case ofwhich F10 is LIQUID:MASS[F26 DENSITY UNIT] Density unitSelect density unit from kg/m3(0), lb/cf(1), lb/USgal(2),lb/UKgal(3).[F27 DENSlTY b] Density bSet density value at standard condition.[F28 TEMP UNIT] Temperature unitSelect temperature unit from deg C(0), deg F(1).[F29 TEMP b] Temperature bSet temperature value at standard condition[F50 TEMP DAMPING] Temperature dampingSet temperature damping, 0 to 99sec.[F52 CABLE LENGTH] Cable length of signalcable(DYC)Set cable length(m) of signal cable.In case of the integral type, cable length is set in 0m.<strong>IM</strong>PORTANTBe sure to set this parameter to correct temperaturemeasurement error, occured by cable length.[F55 A/OUT SELECT] Analog out selectSelect the analog output from FLOW(0), TEMP(1).The following item should be done in case ofwhich F55 is TEMP[F56 TEMP 0%] Temperature at 0%Set temperature value at 0%.[F57 TEMP 100%] Temperature at 100%Set temperature value at 100%.[F58 TEMP ERR OUT] Output selection ofthermometer errorSelect output function when thermometer error from 0%(0),OUTL<strong>IM</strong>IT(H)(1), TEMP f.In case of OUT L<strong>IM</strong>IT(H), it is based on parameter “D30”[F30 1st coef] 1st coefficientSet lst temperature coefficient using the density correction.[F31 2nd coef] 2nd coefficientSet lst temperature coefficient using the density correction.[F32 MASS UNIT] Mass unitSelect mass flow rate unit from kg(0), t(1), lb(2), k lb(3).[F35 T<strong>IM</strong>E UNIT] Time unitSelect time unit from /s(0), /m(1), /h(2), /d(3).[F40 FLOW SPAN] Flow spanSet span flow rate, 0 to 32000.[F45 DAMPING] Flow dampingSet flow damping, 0 to 99sec.5-14 <strong>IM</strong> <strong>01F06A00</strong>-<strong>01EN</strong>