12.07.2015 Views

Prisma Plus LV Switchboards - POWERLAB

Prisma Plus LV Switchboards - POWERLAB

Prisma Plus LV Switchboards - POWERLAB

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DistributionSystem GMulticlip distribution blockCatalogue numbersDD381399PD390660DD381661GeneralCable connection.63/80 A Multiclip distributionblocks04008.04004.For connections, the distribution block uses a proven technique, i.e. spring terminals.Downstream circuits are connected from the front, without screws, to springterminals. Contact pressure does not depend on the operator. It automatically adaptsto the size of the conductor (minimum size = 1mm²). Contacts are insensitive tovibrations and thermal variations.Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a springterminal.Degree of protection: IPxxB.Advantagesb a reliable electrical connection, no maintenance required (tightness guaranteedover time)b the fast connections make phase balancing very easy.b rewiring is very easy if the switchboard is expanded or modified.ApplicationDistribution over half or full rows of modular devices. It is generally supplied by adevice at the head of a group of outgoers (NG125, INS, C60, etc.).Cat. no. selectionDesignationCat. no.80 A Multiclip distribution block, 4P 0400463 A Multiclip distribution block, 4P, 1/2 row 04008Electrical characteristicsb rated insulation level Ui = 500 Vb impulse withstand voltage Uimp = 6 kVb short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations have beentested.b 63/80 A Multiclip distribution blocks:v 4 mm² cable outgoer: Imax = 32 Av 6 mm² cable outgoer: Imax = 40 Av two 6 mm² cables: Imax = 63 A.SupplyVia tunnel terminals up to 25 mm², generally from a device supplying a group ofoutgoers.The tunnel terminals are positioned to facilitate cable entry and screw tightening.They are designed for cables arriving from the top or bottom.Distributionb for the full-row Multiclip, 4P (04004), each phase offers:v 2 connection points for 6 mm² max. cablev 7 connection points for 4 mm² max. cablethe neutral offers:v 4 connection points for 6 mm² max. cablev 13 connection points for 4mm² max. cableb for the half-row Multiclip, 4P (04008), each phase offers:v 2 connection points for 6 mm² max. cablev 2 connection points for 4 mm² max. cablethe neutral offers:v 4 connection points for 6 mm² max. cablev 4 connection points for 4 mm² max. cableEach connection point can receive a single cable, either flexible or rigid.Installationb clipped onto the rear of modular railb screwed to plain or slotted backplateDD381665DD381664Half-row Multiclip distribution block suppliedby an INS switch-disconnector.Multiclip distribution block supplied by a VigiNG125 circuit breaker.Supplied with 100 mm long bared copper connectionsb for full-row Multiclip (04004):v 2 sets of ten 4 mm² connections + 1 set of six 6 mm² connectionsb for half-row Multiclip (04008):v 1 set of ten 4 mm² connections + 1 set of six 6 mm² connections.114

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!