DistributionSystem GMulticlip distribution blockCatalogue numbersPD390661160/200 A Multiclip distributionblocksApplicationDistribution over full rows of modular devices.The distribution block is generally supplied by busbars in enclosures and cubicles.Cat. no. selectionDesignationCat. no.200 A Multiclip, 2P 04012200 A Multiclip, 3P 04013200 A Multiclip, 4P 04014160 A Multiclip, 4P, 1/2 row 04018DD381672DD381670DD381671Electrical characteristicsb rated insulation level Ui = 750 Vb impulse withstand voltage Uimp = 8 kVb short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations have been.b 160/200 A Multiclip distribution blocks:v 10 mm² cable outgoer: Imax = 50 Av two 10 mm² cables: Imax = 63 A.Supplyb direct to terminals:v 50 mm² cables with crimped lugsv 20 x 3 mm flexible barsb from Powerclip insulated busbars in a wall-mount or floor-standing enclosure(04021)b from busbars in the duct of a wall-mount or floor-standing enclosure (04024)b from busbars in the rear of a wall-mount or floor-standing enclosure (04029).Busbar connection04012. Designation Cat. no.Connection between 200 A Multiclip and Powerclip insulated busbars 04021(enclosure)Connection between 200 A Multiclip and busbars in a duct (enclosure) 04024Connection between 200 A Multiclip and rear busbars (enclosure) 0402904013.04014.Distributionb 200 A Multiclip, 2P (04012):v 12 connection points for phase and neutralb 200 A Multiclip, 3P and 4P (04013 and 04014):v 12 connection points for each phasev 18 connection points for the neutralb 160 A Multiclip, 4P, 1/2 row (04018):v 6 connection points for each phasev 9 connection points for the neutralEach connection point can receive a single 10 mm² cable, either flexible or rigid.Installationb clipped onto the rear of modular railb screwed to plain or slotted backplate.Supplied with:b 100 mm long, bared 10 mm² copper connectionsv 200 A Multiclip, 2P, 3P and 4P (04012, 04013 et 04014): 2 sets of 12 connectionsv 160 A Multiclip, 1/2 row (04018): 1 set of 12 connectionsb protection covers for the supply terminals (IPxxB)b the hardware required for the supply terminals.DD381673DD380860DD38067404018.Supply from busbars in the duct of a wallmountor floor-standing enclosure (connection04024).Supply from Powerclip busbars in a wallmountor floor-standing enclosure (connection04021).115

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!