12.07.2015 Views

Intel Pentium III Processor for the SC242 at 450 MHz to 1.0 GHz

Intel Pentium III Processor for the SC242 at 450 MHz to 1.0 GHz

Intel Pentium III Processor for the SC242 at 450 MHz to 1.0 GHz

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Boxed <strong>Processor</strong> Specific<strong>at</strong>ionsFigure 55. Recommended Baseboard Power Header Placement Rel<strong>at</strong>ive <strong>to</strong> Fan PowerConnec<strong>to</strong>r and <strong>Intel</strong> ® <strong>Pentium</strong> ® <strong>III</strong> <strong>Processor</strong>242-Contact Slot Connec<strong>to</strong>rVFan power connec<strong>to</strong>r loc<strong>at</strong>ion(1.56 inches above mo<strong>the</strong>rboardWXMo<strong>the</strong>rboard fan power header should bepositioned within 4.75 inches of <strong>the</strong> fanpower connec<strong>to</strong>r (l<strong>at</strong>eral distance).Table 40. Baseboard Fan Power Connec<strong>to</strong>r Loc<strong>at</strong>ionFig. Ref.Labels Dimensions (Inches) Min Typ MaxVWXApproxim<strong>at</strong>e perpendicular distance of <strong>the</strong> fan power connec<strong>to</strong>rfrom <strong>the</strong> center of <strong>the</strong> 242-contact slot connec<strong>to</strong>rApproxim<strong>at</strong>e parallel distance of <strong>the</strong> fan power connec<strong>to</strong>r from<strong>the</strong> edge of <strong>the</strong> 242-contact slot connec<strong>to</strong>rL<strong>at</strong>eral distance of <strong>the</strong> baseboard fan power header loc<strong>at</strong>ionfrom <strong>the</strong> fan power connec<strong>to</strong>r1.441.454.756.4 Fan He<strong>at</strong>sink Thermal Specific<strong>at</strong>ionsThis section describes <strong>the</strong> cooling requirements of <strong>the</strong> fan he<strong>at</strong>sink solution utilized by <strong>the</strong> boxedprocessor.6.4.1 <strong>Intel</strong> ® Boxed <strong>Processor</strong> Cooling RequirementsThe boxed processor will be directly cooled with a fan he<strong>at</strong>sink. However, meeting <strong>the</strong> processor'stemper<strong>at</strong>ure specific<strong>at</strong>ion is also a function of <strong>the</strong> <strong>the</strong>rmal design of <strong>the</strong> entire system, andultim<strong>at</strong>ely <strong>the</strong> responsibility of <strong>the</strong> system integr<strong>at</strong>or. Refer <strong>to</strong> Section 4.0 <strong>for</strong> processortemper<strong>at</strong>ure specific<strong>at</strong>ions. The boxed processor fan he<strong>at</strong>sink is able <strong>to</strong> keep <strong>the</strong> processortemper<strong>at</strong>ure within <strong>the</strong> specific<strong>at</strong>ions (see Table 25 and Table 26) in chassis th<strong>at</strong> provide good<strong>the</strong>rmal management. For <strong>the</strong> boxed processor fan he<strong>at</strong>sink <strong>to</strong> oper<strong>at</strong>e properly, it is critical th<strong>at</strong> <strong>the</strong>airflow provided <strong>to</strong> <strong>the</strong> fan he<strong>at</strong>sink is unimpeded. Airspace is required around <strong>the</strong> fan <strong>to</strong> ensureth<strong>at</strong> <strong>the</strong> airflow through <strong>the</strong> fan he<strong>at</strong>sink is not blocked. Blocking <strong>the</strong> airflow <strong>to</strong> <strong>the</strong> fan he<strong>at</strong>sinkreduces <strong>the</strong> cooling efficiency and decreases fan life. Figure 53 illustr<strong>at</strong>es an acceptable airspaceclearance <strong>for</strong> <strong>the</strong> fan he<strong>at</strong>sink. It is also recommended th<strong>at</strong> <strong>the</strong> air temper<strong>at</strong>ure entering <strong>the</strong> fan bekept below 45 °C (see Figure 53 <strong>for</strong> measurement loc<strong>at</strong>ion). Again, meeting <strong>the</strong> processor'stemper<strong>at</strong>ure specific<strong>at</strong>ion is <strong>the</strong> responsibility of <strong>the</strong> system integr<strong>at</strong>or. Refer <strong>to</strong> Section 4.0 <strong>for</strong>processor temper<strong>at</strong>ure specific<strong>at</strong>ions.92 D<strong>at</strong>asheet

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!