12.07.2015 Views

NEW - Sobel.rs

NEW - Sobel.rs

NEW - Sobel.rs

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

43... LEDwith highpower LEDDesign :As standard ve<strong>rs</strong>ion but:With flat plastic glass in aluminiumframe.Gear tray/heat sink: Aluminium, compactunit with LED, all electrical componentsand aluminium frame with glass pane,hingeable and detachable, (modular design),isolating plug connection to themains connection terminal, cable retainer.LED: 18 or 24 high-power LED 1W or1.5W, 4,000K, integrated optics withIP65Lampcomp.IP43Windan-load griffsfl. areaA = 0,11m 2AnschlussraumConnectionsectionLPH4-6mBatwing characteristics, light distributionas per the „Multi-Layer“ principle.LR (output reduction):For reducing the luminous flux to 50% intimes of low traffic density. A controllead (LST) is required for this purpose.This cycling procedure happens via thecontrol phase (LST = 230V: 100%; LST =OV: 50%)CL ( constant luminous flux function):Luminous flux is kept on a constant levelover the whole life of the light fitting.Advantages of LED equipped Light Fitting:• pole distances up to 34/30m (LPH 6m) with an illumination that complies with the standards.(Illumination class: 55/54)• up to 65% energy saving per km and year in comparison with an 80W hpmv lamp<strong>NEW</strong> • additional eneregy saving up to 60% by output reduction (half-night switching) via the controlphase. Total energy saving up to 84% (ve<strong>rs</strong>ion..... LED LR)• optimal light distribution via an LED integrated optics (Batwing characteristics)• absolutely equal illumination through the “Multi-Layer” principle i.e. every individual LED illuminatesthe total area, the light curves of the individual LED are overlapping. Any failure of aparticular single LED will not create any dark zones in the road. The uniformity of the illuminationis kept<strong>NEW</strong> • no decrease of luminous flux during the whole life of operation of the LED (ve<strong>rs</strong>ion 43 2401LED CL LR). More energy and cost savings up to 21% are achieved by the omission of the generallyusual “ove<strong>rs</strong>izing” in new project plannings.• ECG with high over-voltage protection especially for application in outdoor areas• fail-safe due to overheating, overload and short circuit protection as well as due to the failureprotection fusing of each individual LED (no black out in case of a failure of any single LED)• eco-friendly, no light pollution in the upper space (“Dark-Sky” requirements are fulfilled)• future orientated with an easily interchangeable gear-tray system (modular concept)LEDType Article no. Lamps/ Power WeightW consumption ca. kg 6)43... LED43 1802 LED 43002 0105 18 x 1,5W 34W 5,043 2401 LED 43002 0101 24 x 1,0W 31W 5,043 2401 LED LR 1) 43002 0111 24 x 1,0W 31/14W 2) 5,143 2401 LED CL LR 1) 3) 43002 0112 24 x 1,0W 25 4) -31W 5) /11-14W 2) 5,11) With output reduction2) Output reduced operation3) With constant luminous flux function4) Initial value5) End of operating life6) Weights without packing materialEnergy cost savingswith use of LED series 43 2401 LEDin comparison with 43 80Note:The data given for the LED is relevant at thetime of print. Actual data is available upon request.Changes due to the technical progresscan be found in the internet underwww.schuch.de.The given values for energy saving are approximate.These are dependent on the individuallamps used and the built-in apparatus. Guarantyclaims based on these data are excluded.Energy costs in %Bitte Subject beachten to technical Sie diechanges, Hinweise imisprints Technischen and erro<strong>rs</strong>. Anhang!Technische Änderungen, Druckfehler und Irrtümer vorbehalten.204

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!