12.07.2015 Views

NEW - Sobel.rs

NEW - Sobel.rs

NEW - Sobel.rs

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>NEW</strong>161/162... ZBfor connection to central power supply unitIP65Application:For connection to group or central batterysystems or to an emergency mainsfor illuminating escape routes.Electrical design:ECG: For operation on 230V AC and220V DC with incorporated fuse for cuttingoff in case of failure according toDIN EN 60598-2-22, VDE 0711-2-22,section 22.6.3. In case of 2-lamp ve<strong>rs</strong>ionwith 2 ECG the lamp circuits and theconnection terminal will be separate.Insulation class: II!162 2.. EVGT 26Type Article no. Lamps/ WeightW about kg 1)with electronic ballast (EVG)161 118 ZB 16110 0032 1 x T 26/18 W 1,5161 136 ZB 16110 0033 1 x T 26/36 W 2,4161 158 ZB 16110 0034 1 x T 26/58 W 3,0with 2 individual electronic ballasts (/2E)162 218/2E ZB 16210 0095 2 x T 26/18 W 2,1162 236/2E ZB 16210 0096 2 x T 26/36 W 2,5162 258/2E ZB 16210 0097 2 x T 26/58 W 4,01) Weights without packing materialFurther series / equipment– insulation class II with self contained battery– polycarbonate diffuser (PC)– stainless steel clips (KE)– plastic/stainless steel (KC) closure– one-sided stainless steel hinge (SC)– Special design for wind powerinstallations on request.for series 161/162... with self-contained battery:–.../B stand-by system =emergency lighting in case of mainsfailure only(series 162... with 1 lamp = 1621.. only)–.../P button for testing the emergency lightfunction– 3h emergency operation timefor series 161/162...with self-contained battery and EVG:– .../MA automatic monitoring the emergency lightfitting according to EN 62034, indication ofthe test results by 2-coloured LED (luminescencediode) at the luminaire.– .../BUS for central monitoring of single fittingsfor ve<strong>rs</strong>ion 161/162... in case of connection tocentral power supply unit:– with separate or integrated monitoring module for connectionto group or central power supply unit with systemfor monitoring each individual luminaire. (For anyinquiry please indicate the make of the equipment used.)– with electronic ballast for voltages: 110V AC/DC, 24V DCFurther equipment please see catalogue section„Dustproof/Waterproof Luminaires“ 161/162....Type 162 218... with legend .../35Self adhesive legends.../33 W .../34 W .../35 Wfor escape route identification acc. to BGVA8 and DIN 4844-2. Sighting distanceacc. to EN 1838 and DIN 4844 = 25m.Accessories / Spare PartsTypeArticle no.Self adhesive legends for series 162 118 and 162 218590/125/33 W 59000 0004590/125/34 W 59000 0005590/125/35 W 59000 0006Emergency exit to the leftEmergency exit to the rightEmergency exit belowFor further accessories and spare parts please see catalogue section „Damp room light fittings“Series 161/162...When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings.Bitte Subject beachten to technical Sie die changes, Hinweise imisprints Technischen and Anhang! erro<strong>rs</strong>.Technische Änderungen, Druckfehler und Irrtümer vorbehalten.266

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!