12.07.2015 Views

NEW - Sobel.rs

NEW - Sobel.rs

NEW - Sobel.rs

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Small Impact Resistant Emergency/Escape SignLight FittingSeries 130/131... B/DApplication:In work and meeting places, humid andwet rooms, to illuminate and indicate escaperoutes.Mechanical Design:Housing: white polycarbonate.Diffuser: injection-moulded, clear polycarbonatewith internal prisms or opalescentwhite (W) if pictograms are used.Hinged and detachable at one end andclosed at the other end with captivestainless steel screw. (Pictograms to beordered separately-see accessories)Electrical connection: 3- or 4-poles.Cable entries: 1 blanking plug M20 ateach end.Mounting system: 2 holes for ceilingmounting. Rubber gaskets and U-washe<strong>rs</strong>for sealing are pressed into the fitting.Options:See “Further Series/Equipment”standardized by Deutsche Bahn AGWiring diagram 131.. D/B maintained/stand-bylight switchWiring diagram 131 1.. B stand-byShock resistance test: RK 1.0 / 10Abattery conductoremergency light fittingbattery conductoremergency light fittingInstallation: Connect battery conductorDecommission: Disconnect battery conductorStand-by operation: Do not connect L1'338180 120131... B/Dwith self-contained batteryT 16131 118/.. B.TC - LElectrical design:NiCd battery, gastight, mounted on thereflector. A constant trickle charge to thebattery ensures readiness of operation atall times.Visual function monitoring the batterycharging process with LED.Electronic deep discharge protectionRecharging time: 24 hou<strong>rs</strong> acc. to EN60598-2-22.... /MA Automatic monitoring of theemergency light fitting acc. toEN 62034. 2-coloured LED onthe light fitting indicate the testresults.Type Article . Lamp/ Operating Flux factor Weightno. W time/h about % 2) about kg 4)maintained or stand-by operation 1)Modes of operation:... B = stand-by operation, in the eventof mains failure, the emergencylamp switches on.... D = maintained operation, in theevent of mains failure, the lampswitches over to battery operation.Connection voltage: 230V, 50HzAmbient temperatures:-5°C up to +30°C for maintained ve<strong>rs</strong>ion-5°C up to +40°C for stand-by ve<strong>rs</strong>ionIP65131 108/45 W B/D1 13110 0014 1 x T 16/8 W 1 45 1,3131 108/36 W B/D3 13110 0015 1 x T 16/8 W 3 36 1,3stand-by operation131 118/39 W B1 13110 0018 1 x TC-L 18 W 1 39 1,3stand-by operation, automatic self-monitoring131 118/17 W B1 MA 13110 0022 1 x TC-L 18 W 1 17 1,1131 118/17 W B3 MA 13110 0024 1 x TC-L 18 W 3 17 1,3maintained operation, automatic self-monitoring131 108/35 W D1 EVG MA 13110 0019 1 x T 16/8 W 1 35 1,21) Only uncompensated3) Weights without packing material2) Ratio effective lamp flux to rated current90298180 9572Emergency Notleuchten Light FittingsBitte Subject beachten to technical Sie die changes, Hinweise im misprints Technischen and Anhang! erro<strong>rs</strong>.Technische Änderungen, Druckfehler und Irrtümer vorbehalten.273

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!