12.07.2015 Views

NEW - Sobel.rs

NEW - Sobel.rs

NEW - Sobel.rs

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

131... LED/. MAwith self-contained battery and automatic self-monitoringIP65Application:In humid, wet and dusty locations incommercial and industrial premises, coldrooms, walkable cool cabins etc. foremergency lighting as well as for illuminatingand indicating the escape routes.Electrical design:NiMH battery mounted on the reflector.A constant trickle charge to the batteryensures readiness of operation at alltimes.Electronic deep discharge protection:Recharging time: 24 h, acc. to EN60598-2-22.Mechanical design:As standard ve<strong>rs</strong>ion but:Reflector: Aluminium white painted.Connection: 4-poleMains voltage: 230 V, 50 Hz.LED: Highpower-LED 1W white, 6.500K.Automatic monitoring the emergencylight fitting acc. to EN 62034. Indicationof the test results by 2-colour LED on thelight fitting (….MA).Modes of operation:Maintained operation: Switch over tobattery operation in case of mains failure.Stand-by operation: Emergency lightswitches on in case of mains failure.Schaltbild Dauer-/BereitschaftsschaltungAdvantages of LED-ve<strong>rs</strong>ion• up to 71% energy saving in comparison with an 8W fluorescent lamp• safety in an emergency, immediate full light (100% luminous flux) even at low temperatures• stable luminous flux in the emergency operation independent from the ambient temperature• outstanding even illumination of the pictogram, fulfills EN 1838 and DIN 4844• reduced battery capacity• little thermal stress• low weight• almost maintenance-free operation due to long operation life of the LED (≥ 50,000h)• no costs for lamp replacementInbetriebnahme: Batterieleitung zusammensteckenAußerbetriebnahme: Batterieleitung trennenBereitschaftsschaltung: L1' nicht anschließenNote:The data given for the LED is relevant at thetime of print. Changes based on technical advancementssee web-site underwww.schuch.deThe given values for energy savings are approximate.These are dependent on the individuallamps used and the built-in apparatus.Guarantee claims based on this data are excluded.Type Article . Qty. LED Operating- Lum.flux Powerno. W time h factor about 1) consumptionmaintained operation131 201 W LED/1 MA 13112 0100 2 x 1 W 1 100 4W131 201 W LED/3 MA 13112 0101 2 x 1 W 3 100 4W1) Ratio effective lamp flux to rated currentEnergy costs in %Energy cost savingsusing LED Series 131...71%130/131... W LED ZB<strong>NEW</strong>for connection to central power supply unitIP65Application:For connection to group or central batterysystems or to emergency mains forilluminating and identifying escaperoutes.Electrical design:ECG: For operation on 230V AC and220V DC with incorporated fuse for selectivecutting off in case of failureaccording to DIN EN 60598-2-22, VDE0711-2-22, section 22.6.3.LEDType Article no. . Qty. LED Power/ LED WeightW consumption lm/W about kg 1)Special design for wind powerinstallations on request.Bitte Subject beachten to technical Sie die changes, Hinweise im misprints Technischen and Anhang! erro<strong>rs</strong>.Technische Änderungen, Druckfehler und Irrtümer vorbehalten.274130 201 W LED ZB 13010 0001 2 x 1W 4 W 100 0,4130 601 W LED ZB 13010 0002 6 x 1W 8 W 100 0,5131 201 W LED ZB 13112 0001 2 x 1W 4 W 100 0,4131 601 W LED ZB 13112 0002 6 x 1W 8 W 100 0,51) Weights without packing materialSubject to technical changes, misprints and erro<strong>rs</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!