12.07.2015 Views

NEW - Sobel.rs

NEW - Sobel.rs

NEW - Sobel.rs

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Polyester Damp Room Emergency Light Fittings(Insulation Class I)Series 163/164...Application:In workshops and to illuminate and indicateescape routes according to DIN VDE0108.Mechanical design:Enclosure: glass fibre reinforced polyesterwith foamed polyurethane gasket.Diffuser: clear, stippled, impact resistantacrylic glass (PMMA) or polycarbonateglass (PC), hinged on one side.Fastene<strong>rs</strong>: single plastic clamps (KK). Alsoavailable with stainless steel clamps (KE)on request.Reflector: removable white sheet steel,complete with electronic components.Rotary fastene<strong>rs</strong> for quick assembly.Electrical connection: 3/4-pole connectionterminal.Cable entries: Variable, closed knock-outson the short and long sides, and on thetop, for looping the mains cable. 2 blankingplugs M20.Through-wiring: Classic, up to 7 x2,5mm² or 5 x 4mm² possible. Alternativelylooping the cable at one end.Mounting system: 2 holes for ceilingmounting. Rubber gaskets and U-washe<strong>rs</strong>for sealing are supplied inside thefitting.Wiring diagram 163... maintainedbattery conductorlight switchemergency light fittingWiring diagram 164... maintainedElectrical design:Built-in NiCd battery, a constant tricklecharge to the battery ensures readinessof operation at all times.Visual function monitoring the batterycharging process with LED.Electronic deep discharge protectionRecharging time: 24 hou<strong>rs</strong> acc. to EN60598-2-22.Modes of operation:Maintained mode = change-over to batteryoperation on mains failure. With the2-lamp ve<strong>rs</strong>ion, only one lamp is operatedas emergency lighting (Series164…).Mains voltage: 230V, 50HzAmbient temperature:-5°C to +30°C for maintained mode-5°C to +40°C for stand-by modeSCHUCH quality - Your advantage:light switchbattery conductormainsmains/emergencyemergency light fittingInstallation: connect battery conductorDecommission: disconnect battery conductorStand-by operation: do not connect L1'• quality damp room light fitting with higher than average mechanical strength and chemicalresistance- robust glass fibre reinforced polyester enclosure- robust, modified PMMA diffuser (alternatively PC) with thicker walls also in the critical areas (corne<strong>rs</strong>)- reliable and infallible sealing, due to non-aging, weather and chemical resistant polyurethane gasketsituated inside a deep groove• easy to install and maintain- fast dismantling and assembly of the reflector using rotary fastene<strong>rs</strong> on moulded-in studs- large terminal compartment for up to to 7 x 2.5mm² or 5 x 4mm² terminals- problem-free, single-handed installation (2-point suspension)- easily adaptable to all local structural conditions due to the variable cable entries on the short andlong sides, as well as the top- quick and economic single-end IN-OUT wiring instead of the classic through wiring for strip lighting• permanently ready for operation by constant trickle charge to the battery• visual function monitoring with LED• electronic deep discharge protection163/164...with self-contained batteryIP65T 26Type Article . Lamp/ Flux factor Weightno. W about % 2) about kg 3)163...Series 163... Series 164...163 158/...<strong>NEW</strong>1 h operation time 1)163 136/18/1 16310 0001 1 x T 26/36 W 18 3,4163 158/15/1 16310 0002 1 x T 26/58 W 15 4,3164 218/25/1 16410 0012 2 x T 26/18 W 25 3,5164 218/60/1 16410 0040 2 x T 26/18 W 60 4,7164 236/18/1 16410 0001 2 x T 26/36 W 18 5,2164 258/15/1 16410 0002 2 x T 26/58 W 15 6,6163 136/18/1 EVG 16310 0005 1 x T 26/36 W 18 3,2163 158/15/1 EVG 16310 0006 1 x T 26/58 W 15 3,4164 218/25/1 EVG 16410 0015 2 x T 26/18 W 25 3,0164 236/18/1 EVG 16410 0005 2 x T 26/36 W 18 4,1164 258/15/1 EVG 16410 0009 2 x T 26/58 W 15 4,9Emergency Notleuchten Light Fittings1) 3h emergency operation on demand2) Ratio effective lamp fluxto rated current3) Weights without packing materialBitte Subject beachten to technical Sie die changes, Hinweise imisprints Technischen and Anhang! erro<strong>rs</strong>.Technische Änderungen, Druckfehler und Irrtümer vorbehalten.267

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!