12.07.2015 Views

NEW - Sobel.rs

NEW - Sobel.rs

NEW - Sobel.rs

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Explosion-Protected Installation SwitchSeries 8030...Applications:For switching lighting installations in hazardousareas of Zones 1, 21 and 2, 22.Pay attention to switching capabilities admissible.Design:Housing: Made from impact resistantglass fibre reinforced polyester resin. Lidmade from polyamide. Rotary handlewith fluorescent arrow. 90° switching.Connection terminals:finely stranded: 1,5 ... 2,5mm 2 .single-wire: 1,5 ... 4,0mm 2Cable entry:1 cable gland M25 x 1,5 and2 plugs M25 x 1,5 are part of thedelivery.2nd cable gland upon request.Mounting: By means of 2 screws.Electrical DataRated Voltage 690V AC, 250V DCSwitching capacilityAC-1 16A 690VAC-15 16A 415VAC-3 8A 500VAC-3 4A 690VDC-1 10A 24VDC-1 6A 60VDC-1 6A 110V 1)DC-1 6A 220V 2)Number of poles: 2-pole1) 2 contacts connected in series2) 3 contacts connected in series8030/.for voltages up to 500 VEC-Type Examination Certificate:PTB 02 ATEX 1026LCIE 03 ATEX 6306Marking:II 2 G Ex de IIC T6II 2 D Ex tD A21 IP65 T80°CII 2 G Ex de IIC T6II 2 D Ex tD A21 T80°CIP65Ignition protection: e (increased safety)Rated voltage: 690V AC, 250V DCRated current: max. 16APermissible ambient temperature:–50°C bis +60°C.Type Article no. Switch Ident no. Weightve<strong>rs</strong>ionca. kg8030/A 80300 0001 ON-OFF 2 poles 8030/51-033 0,568030/W 80300 0002 Pole changing switch 8030/51-035 0,57Explosion-Protected Junction BoxSeries 8118...Applications:For transmission and distribution of electricalenergy in hazardous areas of Zones1 and 2.Design:Housing: Made from impact resistantglass fibre reinforced polyester resin.Connection terminals: 5 hood-type terminals(1 of them serves for earth connection)for a max. conductor size of 2x6.0mm².Cable entry:8118/4:4 cable glands M25 x 1,5 +2 plugs M25 x1,5.8118/6:6 cable glands M25 x 1,5Mounting system:See dimensional drawings.8118/48118/6Depth 64mmDepth 64mm8118/.for voltages up to 750VEC-Type Examination Certificate:PTB 99 ATEX 3103Marking:II 2 G Ex e IIC T5/T6II 2 D Ex tb IIIC T80-95°C DbII 2 G Ex e IICT5/T6II 2 D Ex tb IIICT80-95°CIP66Ignition protection: e (increased safety)Rated voltage: 750V ACPermissible ambient temperature:T5: –60°C bis +40°CT6: – 60°C bis +55°C.Rated current: max. 35AType Article no. Cable glands Weightca. kg8118/4 81180 0001 4 x M25 x 1,5 0,578118/6 81180 0002 6 x M25 x 1,5 0,61Bitte Subject beachten to technical Sie die changes, Hinweise im misprints Technischen and erro<strong>rs</strong>. Anhang!Technische Änderungen, Druckfehler und Irrtümer vorbehalten.68

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!