Applications Note 1-6:Deadweight test apparatus possess the important inherent ability <strong>of</strong> applyingexactly the same loads to the sensor being calibrated regardless <strong>of</strong>whether loads are increasing or decreasing. Insight into the value <strong>of</strong> thisinherent advantage <strong>of</strong> deadweight calibration systems follows in the discussion<strong>of</strong> hydraulic test systems.HydraulicIn higher-load-range calibrations, a reference load cell is installed into theload path in series with the device to be calibrated where the assembly ishydraulically loaded <strong>and</strong> the output <strong>of</strong> the test load cell is compared to theoutput <strong>of</strong> the reference load cell. Calibrations <strong>of</strong> this type are known ascomparison calibrations as the sensor under test is being compared to thereference load cell. Moorehouse Instruments <strong>of</strong> Pennsylvania manufacturesload frames <strong>of</strong> this type. As one might suspect, the precision <strong>of</strong> this type <strong>of</strong>calibration is limited by the precision <strong>of</strong> the reference load cell otherwiseknown as the Òtransfer st<strong>and</strong>ardÓ. A calibration showing zero nonlinearity<strong>and</strong> hysteresis simply means that no substantial difference exists betweenthe load cell being calibrated <strong>and</strong> the reference load cell. Such results donot imply zero error. Typically, the reference load cell is chosen to showbetween three <strong>and</strong> ten times lower nonlinearity <strong>and</strong> hysteresis errors thanthe sensor being calibrated. Accordingly, to calibrate a load cell to ±.1% <strong>of</strong>full scale output (FSO) nonlinearity <strong>and</strong> hysteresis, the reference load cellshould show between ±.03% <strong>and</strong> ±.01% FSO nonlinearity <strong>and</strong> hysteresis.To achieve traceable high performance results with this type <strong>of</strong> apparatus,one must consider that the loads applied will decay with respect to time dueto seal leakage around the hydraulic cylinder piston seal. High pressurehydraulic lines provided with this type <strong>of</strong> system are <strong>of</strong>ten elastomeric innature <strong>and</strong> it is common to change to stainless steel tubing thereby reducingthe applied force decay rate due to hydraulic line expansion. Often,high speed digital data acquisition systems are used to collect many samples<strong>of</strong> both the transfer st<strong>and</strong>ard <strong>and</strong> the sensor under test at each inputload level where this data is averaged. This has the effect <strong>of</strong> averagingnoise to zero <strong>and</strong> reducing the uncertainty due to load decay.<strong>The</strong> <strong>Art</strong> <strong>of</strong> <strong>Practical</strong> <strong>and</strong> <strong>Precise</strong> <strong>Strain</strong> <strong>Based</strong> Measurement 2nd Edition © 1999 CHAPTER 1-31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!