12.07.2015 Views

The Art of Practical and Precise Strain Based ... - Webprofile.info

The Art of Practical and Precise Strain Based ... - Webprofile.info

The Art of Practical and Precise Strain Based ... - Webprofile.info

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Strain</strong>-<strong>Based</strong> Measurement Introduction:ity internal vacuum sealed by hermetic methods, with the exception <strong>of</strong>the Mallory bonded capsule. As a result, most miniature sensors arefabricated using various epoxy materials that would outgas <strong>and</strong> deterioratean internal vacuum, even if one were initially provided.FIGURE 1-42. <strong>The</strong> Electrically-Referenced Absolute Pressure Sensor:AppliedPressureSeal (usually epoxy)Lead wiresAtmospheric Pressure Sealed InsideOutput14.7 mV0@ 1mV/PsiaPressure14.7 Psia( 0 Psig)Sensor Zero BeforeTrimming<strong>The</strong> zero level <strong>of</strong> the Electrically-Referencedpressure sensor is trimmed in the positivedirection.<strong>The</strong> use <strong>of</strong> the electrically-referenced method implies that, if the sensoris pressure-cycled from a high vacuum to a greater than 14.7 psia pressure,the bending diaphragm will progress through the stress-strainÒinflection pointÓ where the membrane transitions from negative topositive bending. Due to the asymmetry <strong>of</strong> the flush-diaphragm supportingclamp structure, the sensitivity <strong>of</strong> the diaphragm can be mismatchedby as much as ± 3% between positive <strong>and</strong> negative bending.This characteristic will not create error provided that the sensor hasbeen calibrated from a close-to-zero psia pressure to the maximumrange <strong>of</strong> the device. Properly calibrated, the inflection error becomes anintegral component <strong>of</strong> the nonlinearity error <strong>of</strong> the sensor.Another consideration in the Òtrue-psiaÓ versus the Òelectrically-referencedÓissue is that if no pressure difference exists between the insidereference cavity <strong>of</strong> the sensor <strong>and</strong> the outside world, then no tendencyCHAPTER 1-74 <strong>The</strong> <strong>Art</strong> <strong>of</strong> <strong>Practical</strong> <strong>and</strong> <strong>Precise</strong> <strong>Strain</strong> <strong>Based</strong> Measurement 2nd Edition © 1999

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!