12.07.2015 Views

The Art of Practical and Precise Strain Based ... - Webprofile.info

The Art of Practical and Precise Strain Based ... - Webprofile.info

The Art of Practical and Precise Strain Based ... - Webprofile.info

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Strain</strong>-<strong>Based</strong> Measurement Introduction:As in accelerometer calibration, the gravimetric method may be usedwith broadb<strong>and</strong> noise inputs, sinusoidal or discrete-frequency inputsgenerated by an electrodynamic shaker to determine the load cell transferfunction.Pressure Transducers:Pressure sensors may be calibrated by many different methods for the purpose<strong>of</strong> determining the sensor transfer function where some <strong>of</strong> these methods arediscussed as follows:Deadweight PressurePressure transducers are statically calibrated by means <strong>of</strong> the deadweighttester where calibrated masses are sequentially added to a platformthat is supported by a precision piston. <strong>The</strong> pressure is increasedmanually or automatically, by either a ram or controlled-pressure regulator,to the point where the pressure, generated by the calibratedweights acting over the area <strong>of</strong> the precision piston, is balanced <strong>and</strong> thepiston is free-floating. <strong>The</strong> precision <strong>of</strong> this type <strong>of</strong> calibration systemrelates to the area difference between the piston <strong>and</strong> bore within whichit moves. Traceable uncertainties <strong>of</strong> as low as .0004% <strong>of</strong> applied pressureare achievable with deadweight calibrators where the piston <strong>and</strong>bore are precision lapped to minimize area differences. As the area differencebetween the piston <strong>and</strong> bore results in a leakage path, it is commonfor the piston to slowly settle where the pressure will ultimatelydecay to zero. Operating procedures for deadweight pressure calibratorswill <strong>of</strong>ten specify that the weights be manually rotated to distributethe fluid film <strong>and</strong> minimize friction while data is collected at each inputlevel. <strong>The</strong> sensor to be calibrated is in communication with the balancedpressure reservoir <strong>and</strong> the sensor output is recorded. As with allstatic-calibration methods, phase data is not available.CHAPTER 1-34 <strong>The</strong> <strong>Art</strong> <strong>of</strong> <strong>Practical</strong> <strong>and</strong> <strong>Precise</strong> <strong>Strain</strong> <strong>Based</strong> Measurement 2nd Edition © 1999

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!