12.07.2015 Views

Systems Reference Library - All about the IBM 1130 Computing ...

Systems Reference Library - All about the IBM 1130 Computing ...

Systems Reference Library - All about the IBM 1130 Computing ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Power OnThis switch is used to turn on <strong>the</strong> power supplieswithin <strong>the</strong> P-C.Power OffThis switch is used to turn off <strong>the</strong> power supplieswithin <strong>the</strong> P-C.Power OnThis light is used to indicate that <strong>the</strong> P-C powersupplies are operative.Lamp TestThis switch is pressed to apply lamp voltage to allconsole lamps. Its purpose is to verify operation ofall console lamps.WaitThis light is used to indicate that <strong>the</strong> P-C is in loador display mode, has been halted by a wait instruction,or has been halted by <strong>the</strong> operator pushingSTOP or IMMED STOP.RunThis light is used to indicate that <strong>the</strong> P-C is operatingunder program control.AlarmThis light is used to indicate that <strong>the</strong> operationsmonitor has timed out. The customer may installan audible alarm to operate in conjunction with <strong>the</strong>alarm light. See "Operations Monitor" section.Emergency Pull SwitchThis pull switch is for emergency use only. If it ispulled out, all electrical power within <strong>the</strong> 1801/1802is turned off, including power to <strong>the</strong> blowers thatcool <strong>the</strong> electronic circuitry. Turning <strong>the</strong> blowersoff in this manner may damage some of <strong>the</strong> circuitry.This switch must be reset by a customer engineer.Console InterruptThis switch (CONSOLE INTR) enables <strong>the</strong> operator tointerrupt P-C operation. The console interrupt levelis assigned by <strong>the</strong> customer. The program toggleswitches may be used in conjunction with consoleinterrupt to specify <strong>the</strong> console interrupt routine.However, this relationship between <strong>the</strong> programswitches and console interrupt exists only by virtueof <strong>the</strong> program. There is no internal relationshipbetween <strong>the</strong> two.Load IThis switch is used with <strong>the</strong> mode switch in <strong>the</strong> loadposition to transfer <strong>the</strong> contents of <strong>the</strong> data entrytoggle switches to <strong>the</strong> I-register. The P-C is in <strong>the</strong>stopped condition when it terminates <strong>the</strong> load Ioperation.ResetThis switch is used to reset all basic timing, controls,registers (except index registers and addressregisters), and I/O devices. The interrupt maskregister is reset with all bits on. The digital inputand digital-analog output registers are not reset.The reset switch is effective only when <strong>the</strong> P-C isnot in a run state, as indicated by <strong>the</strong> run light beingoff.Immediate StopThis switch (IMMED STOP) stops <strong>the</strong> P-C at <strong>the</strong> endof <strong>the</strong> core storage cycle in operation when <strong>the</strong> switchcontacts close.<strong>All</strong> basic timing, controls, registers (exceptindex registers and address registers), and I/O devicesare reset. IMMED STOP can also be used tostop data channel (cycle stealing) operations thatare no longer under program control.StartIf <strong>the</strong> ready light is on, this switch initiates P-Coperations, as specified by <strong>the</strong> mode switch.Processor-Controller Console 83

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!