2. Pressure build-up phase.The system pressure is increased until the setpoint is reached.The pressure build-up takes place over a ramp time. If thesetpoint is not reached within a given time, a warning or analarm can be given, and the pumps can be stopped at thesame time.9.7.25 Emergency run (4.3.5)H [psi]1. Filling phase 2. Pressure build-up phaseTM04 6198 5009Fig. 67Filling timeRamp timeFilling and pressure build-up phasesTime [sec]TM03 9037 3207Fig. 68Emergency runDescriptionWhen this function has been activated, the pumps will keeprunning regardless of warnings or alarms. The pumps will runaccording to a setpoint set specifically for this function.Setting range• Activation of the function.• Setting of pump speed.• Setting of number of pumps.• Setting of filling pressure.• Setting of maximum filling time.• Setting of warning or alarm + stop.• Setting of ramp time for the pressure build-up phase.Setting via control panel1. Mark the Settings menu with2. Mark Secondary functions with or , and press .3. Mark Soft pressure build-up with or , and press.4. Mark Speed with or .5. Set the value with or , and save with .6. Mark Number of pumps with or .7. Set the value with or , and save with .8. Mark Filling pressure with or .9. Set the value with or , and save with .10.Mark Max. time with or .11.Set the value with or , and save with .12.Mark Warning or Alarm + stop with or , and press.13.Mark Ramp time with or .14.Set the value with or , and save with .15.Mark Activated, and press .Factory settingThe function is deactivated.CautionSetting range• Setting of digital input (9.7.26 Digital inputs (4.3.7)).• Setting of digital output (9.7.31 Digital outputs (4.3.9)).• Setting of setpoint for emergency run.Setting via control panel1. Mark the Settings menu with2. Mark Secondary functions with or , and press .3. Mark Emergency run with or , and press .4. Mark Go to setting of digital input with or , andpress .5. Select a digital input with or , and press .6. Mark Emergency run with or , and save with .7. Return by pressing twice.8. Mark Go to setting of digital output with or , andpress .9. Select a digital output with or , and press .10.Mark Emergency run with or , and save with .11.Return by pressing twice.12.Mark Setpoint, emergency run with or .13.Set the value with or , and save with .NoteIn case of sensor fault, both main and standbypumps will run at 100 % speed!When this function has been set as describedabove, it can also be activated via the displaySystem operating mode (2.1.1).47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!