10. OTHER FUNCTIONS10.5 Engine Display Setup (INSTRUMENTS menu)Set your engine’s specifications on the [INSTRUMENTS] menu to get correct informationon the engine displays.80° to 320°F80° to 320°F80° to 320°FItem Options RemarksENGINE RPM 4000, 6000, 8000 rpm Set max. rpm.MAX OILPRESSUREENGINE BOOSTPRESSUREENGINE COOLANTPRESSUREFUEL PRESSUREENGINETEMPERATUREENGINE OILTEMPERATURETRANSMISSIONTEMPERATURE600kPa/6Bar/80Psi800kPa/8Bar/120Psi1000kPa/12Bar/160Psi160kPa/1Bar/24Psi200kPa/2Bar/32Psi320kPa/4Bar/40Psi320kPa/2Bar/48Psi520kPa/4Bar/64Psi600kPa/6Bar/96Psi320kPa/2Bar/48Psi520kPa/4Bar/64Psi600kPa/6Bar/96Psi30 to 150°C/80 to 320°F50 to 210°C/120 to 400°F30 to 150°C/80 to 320°F50 to 210°C/120 to 400°F0 to 150°C/80 to 320°F50 to 210°C/120 to 400°FSet max. oil pressureSet engine boost pressure rating.Set engine coolant pressurerating.Set fuel pressure rating.Set engine temperaturerange.Set engine oil temperaturerange.Set transmission temperaturerange.10-7