13. INSTALLATIONHow to extend cable length (GPA-017S)The standard cable is 10 m long. For extension, in case of the GPA-017S, an antennacable set of 30 m or 50 m is available. Extension cable cannot be used with the GPA-017.Fabricate the end of the antenna cable and attach the coaxial connector. See the precedingpage.ANTENNA UNIT GPA-017SConversion cable assy.: Connector1 mTransducerAntenna cable30 m or 50 m 1 mFabricate locally.To display unitConnect the transducer cable to the XDR port.Transducer and sensorUse the optional conversion cable (02S4147) to connect the optional speed/temperaturesensor and the transducer to the XDR port.Connect to XDR portat rear of display unitMJ-A10SPFMJ-A6SRMDMJ-A10SRMDTape connectors withvulcanizing tape andthen vinyl tape towaterproof them.Bind tape ends withcable ties to preventtape from unraveling.FromsensorFromtransducer13-17