30.07.2015 Views

Shodex Catalogue 2013-2015.pdf - Analytics Shop

Shodex Catalogue 2013-2015.pdf - Analytics Shop

Shodex Catalogue 2013-2015.pdf - Analytics Shop

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Speciation of arsenic2000Standard arsenic compounds110002 3 45 6Sample : Arsenic compounds, 50μL1. Monomethylarsonic acid2. Arsinic acid3. Dimethylarsinic acid4. Arsenobetaine5. Tetramethylarsonium6. Trimethylarsine oxideLC/MS analysis of perchloric acid and oxyhalidesClO 4-Sample : 5μLClO - 4 0.2μg/LClO - 3 5μg/LBrO - 3 5μg/LCl - 1mg/Lm/z 99Standard AnalysisColumns0 100 200 300 400 500 600 700 800 900 10001100 1200 secClO3 - BrO 3-m/z 832000100012340 100 200 300 400 500 600 700 800 900 10001100 1200 secColumn : <strong>Shodex</strong> RSpak NN-614Eluent : 5mM HNO 3 /8mM NH 4 NO 3 aq.Flow rate : 0.8mL/minDetector : IC-ICP-MS(SIM m/z 75)20001000231LC/MS analysis of nonylphenol ethoxylatesColumnEluentFlow rateDetectorUrine from a patient witharsenic poisoning: <strong>Shodex</strong> MSpak GF-310 4D: (A) CH 3 CN, (B): H 2 OA/B=30/70(7min) (23min) A/B=90/10: 0.5mL/min: ESI-MS(SIM Positive)Urine of a healthy person45 6100 200 300 400 500 600 700 800 900 100011001200 secSource:Noriko Tsunoda,Pharmacia. 1998, vol.34, No.12, p.1237-1241Sample : Nonylphenol ethoxylates, 20μLSource:Mr. Yoshinari Kobuke (Environmental Science Institute of Hyogo Prefecture),Basic Study of Chemical Substances in LC/MS,10th Symposium on Environmental Chemistry Program and Abstracts, 542-543, 2001.0 5 10 15 20 minLC/MS analysis of additivesSample : Cup of instant noodles (styrene foam) 1000mg/L, 5μL001 2 3 41 2 3 4Cl -m/z 127m/z 35Column : <strong>Shodex</strong> RSpak JJ-50 2DEluent : 50mM Ammonium formate aq./CH 3 CN=25/75Flow rate : 0.2mL/minDetector : ESI-MS(SIM Negative)Column temp. : 30˚CThe analysis of additives that are present in polymers usuallyrequire sample pretreatment steps. However, by using sizeexclusion chromatography columns, easy and high sensitiveanalysis of additives was achieved without any pretreatmentsteps. The target additives are separated from the polymer andthis allows introducing only the low molecular fraction (whichcontains the additives) into MS.UV(210nm)m/z 1176(Negative)5 6 7 8 9 10 11 12 13 14 15 16min5 6 7 8 9 10 11 12 13 14 15 16minColumn : <strong>Shodex</strong> GPC KF-402HQ x 2Eluent : THFFlow rate : 0.3mL/minDetector : UV(210nm), APCI-MS(SIM)Column temp. : 40˚Cnot detectedIRGANOX ® 1010Columns for Polymer-based Hydrophilic Interaction Chromatography (HILIC) Aqueous/Organic SEC Columns Organic SEC (GPC) Columns[Columns for LC/MS Analysis] Columns for Polymer-based Reversed Phase Chromatography61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!