Liebert Challenger™ 3000 with iCOM Installation Manual - 3 ... - DCES

Liebert Challenger™ 3000 with iCOM Installation Manual - 3 ... - DCES

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NOTICEGlycol/GLYCOOL-Cooled Models—Self-Contained CompressorRisk of debris or precipitate clogging pipes. Can cause equipment damage.Galvanized pipe must not be used in or <strong>with</strong> systems or units that contain glycol. Thephosphates in the inhibitor can react <strong>with</strong> the zinc in the galvanized pipe, precipitating aninsoluble material that can eventually foul the system.Fluid-cooled condensers have small internal flow passages. To avoid clogging and otherresulting system operation problems, install a 16-20 mesh filter in the fluid supply line to theindoor unit. The filter should be located where it can be easily serviced or replaced.Do not install unit on open loop systems. Debris carried by the fluid will clog the brazed platecondenser.NOTICERisk of improper installation. Can cause equipment or structural damage.Supply and return lines must be supported in a way that keeps their weight from bearing onthe piping of the unit, drycooler or pumps. Failure to support piping can strain theequipment’s structural integrity.A relief valve must be installed in the system to avoid the possibility of burst pipes. This valvemay be obtained from the supplier as an option or obtained from another vendor.Emerson recommends installing manual service shut-off valves at the supply and return connectionsto each unit. This enables routine service and/or emergency isolation of the unit. In addition, multiplepump packages require a check valve at the discharge of each pump to prevent back flow through thestandby pump(s).To facilitate filling, installation of hose bibs at the lowest point of the system is recommended.Consideration of the minimum glycol temperature to be supplied from the drycooler will determine ifthe need exists to insulate the glycol supply and return lines. Insulation will prevent condensation onthe glycol lines in low ambient conditions.All fluid piping must comply <strong>with</strong> local codes. Care in sizing pipes will help reduce pumping powerand operating costs.Table 13 Room dew point temperaturesDry Bulb°F (°C)70 (21.1)70 (21.1)72 (22.2)72 (22.2)75 (23.8)75 (23.8)Wet Bulb°F (°C)57.2 (14.0)58.5 (14.7)58.9 (24.9)60.0 (15.5)61.2 (16.2)62.5 (16.9)RelativeHumidity455045504550* Minimum glycol temperature before condensation will occur.Dew Point*°F (°C)48.0 (8.9)50.5 (10.3)50.0 (10.0)52.4 (11.3)52.4 (11.3)55.0 (12.7)43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!