22.08.2015 Views

Liebert Challenger 3000 with iCOM

Liebert Challenger™ 3000 with iCOM Installation Manual - 3 ... - DCES

Liebert Challenger™ 3000 with iCOM Installation Manual - 3 ... - DCES

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important safety instructions that should be followed during the installationand maintenance of the <strong>Liebert</strong> <strong>Challenger</strong> <strong>3000</strong> . Read this manual thoroughly before attempting toinstall or operate this unit.Only qualified personnel should move, install or service this equipment.Adhere to all warnings, cautions and installation, operating and safety instructions on the unit and inthis manual. Follow all operating and user instructions.! WARNINGRisk of electric shock. Can cause injury or death.Disconnect local and remote power supplies before working <strong>with</strong>in.Before proceeding <strong>with</strong> installation, read all instructions, verify that all the parts are includedand check the nameplate to be sure the voltage matches available utility power.The <strong>Liebert</strong> <strong>iCOM</strong> ® microprocessor does not isolate power from the unit, even in the “unit off”mode. Some internal components require and receive power even during the “unit off” mode of<strong>Liebert</strong> <strong>iCOM</strong> control.The factory-supplied optional disconnect switch is inside the unit. The line side of this switchcontains live high-voltage.The only way to ensure that there is NO voltage inside the unit is to install and open a remotedisconnect switch. Refer to unit electrical schematic.Follow all local codes.! WARNINGRisk of explosive discharge from high-pressure refrigerant. Can cause injury or death.This unit contains fluids and gases under high pressure. Relieve pressure before working <strong>with</strong>piping.! WARNINGRisk of refrigerant system rupture or explosion from overpressurization. Can causeequipment damage, injury or death.Local building or plumbing codes may require that a fusible plug or other type of pressurerelief device be installed in the system.For systems requiring EU CE compliance (50Hz), the system installer must provide andinstall a discharge pressure relief valve rated for a maximum of 500psig (34bar) in the highside refrigerant circuit. Do not install a shutoff valve between the compressor and thefield-installed relief valve. The pressure relief valve must be CE certified to the EU PressureEquipment Directive by an EU “Notified Body.”NOTEThe <strong>Liebert</strong> indoor cooling unit has a factory-installed high-pressure safety switch in the highside refrigerant circuit. A pressure relief valve is provided <strong>with</strong> <strong>Liebert</strong> Lee-Temp condensers.Consult local building codes to determine whether the <strong>Liebert</strong> Fan Speed Control and VFDcondensers will require field-provided pressure relief devices. A fusible plug kit for <strong>Liebert</strong> FSCand VFD condensers is available for field installation.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!