29.09.2015 Views

ALPHA Distribution Boards and Terminal Blocks

ALPHA 400 - DIN Wall-Mounted Distribution Boards - Delta Control

ALPHA 400 - DIN Wall-Mounted Distribution Boards - Delta Control

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens AG 2010<br />

<strong>ALPHA</strong> 8HP Molded-Plastic <strong>Distribution</strong> Systems<br />

Introduction<br />

Installation conditions<br />

Installation Measures Climatic conditions according to DIN 50010 Special operating <strong>and</strong> ambient<br />

conditions<br />

Indoor No further measures necessary An indoor climate is an environment in rooms that are<br />

designed so that objects are largely separated from the<br />

direct influence of an open-air climate<br />

External<br />

Outdoor<br />

E.g. protected installation or protective<br />

cover, if necessary with<br />

additional walls <strong>and</strong> door (protective<br />

cabinet).<br />

Only permissible with measures<br />

as for external installation<br />

An external environment is an environment in rooms that are<br />

designed so that objects are protected against direct sunlight<br />

<strong>and</strong> precipitation <strong>and</strong>, if necessary, against wind, but<br />

are otherwise exposed to an open-air climate.<br />

An open-air climate is an environment that affects objects in<br />

the open air<br />

If the operating <strong>and</strong> ambient conditions<br />

differ from the st<strong>and</strong>ard conditions to<br />

DIN VDE 0660 Part 500, Item 6.1, appropriate<br />

measures must be taken to protect <strong>and</strong><br />

maintain the operating capability of the<br />

switchgear assembly for "Special operating<br />

<strong>and</strong> ambient conditions" according to<br />

Item 6.2 (mechanical protection, ventilation,<br />

indoor heating, breathers, etc.).<br />

Conversion from Pg to metric screw connections<br />

We tested a new option for using metric screw connections with<br />

the 8HP molded-plastic distribution system. The results of this<br />

test showed that the Pg openings listed in the following table are<br />

also able to accommodate metric screw connections. We have<br />

used metric screw connections with lock nuts. Appropriate sealing<br />

washers are used in order to ensure degree of protection<br />

IP65.<br />

The values for the tested conversions from Pg to<br />

metric screw connections are shown in the following table.<br />

The knockouts in the enclosure base parts need to be drilled out.<br />

Heavy-gauge threaded joints Lock hasp diameter Metric screw connection Lock hasp diameter fits Lock hasp diameter must be<br />

enlarged to<br />

mm<br />

mm<br />

Pg 13.5 20.4 M20 ✔ --<br />

Pg 16 22.5 M25 -- 25.4<br />

Pg 21 28.3 M32 -- 32.4<br />

Pg 29 37 M40 -- 40.4<br />

Pg 36 47 M50 -- 50.5<br />

Pg 42 54 M63 -- 63.6<br />

Pg 48 59.3 M63 -- 63.6<br />

8<br />

■ Design<br />

The distribution system comprises five enclosure sizes with a<br />

basic size of 307 mm.<br />

The enclosures have knockouts for flange openings <strong>and</strong> cable<br />

entries. They can be used for distribution board applications as<br />

well as for st<strong>and</strong>-alone installations.<br />

The covers are available in opaque or transparent versions<br />

(size 2.5 only available in the transparent version).<br />

The covers are equipped with quick-acting locks for tool actuation.<br />

These can be replaced with locks for manual actuation.<br />

The mounting depth of the enclosure is 147 mm. For enclosure<br />

size 2 there is also a cover for a mounting depth of 212 mm, <strong>and</strong><br />

for enclosure size 2.5 there is a transparent cover for a mounting<br />

depth of 185 mm.<br />

Intermediate frames can be used to increase the mounting<br />

depth of size 3 <strong>and</strong> 4 enclosures. Several intermediate frames<br />

can be used together. Each intermediate frame increases the<br />

mounting depth by 92.5 mm.<br />

Installation conditions for different climatic conditions, "Application<br />

– Installation Conditions". If installed in rooms with high humidity<br />

<strong>and</strong> strongly fluctuating temperatures, suitable measures<br />

must be taken (e.g. ventilation, indoor heating) to prevent the<br />

generation of harmful condensation water. In the event of extreme<br />

temperature fluctuations, breathers must be installed.<br />

Siemens ET A1 · 10/2009<br />

8/7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!