29.09.2015 Views

ALPHA Distribution Boards and Terminal Blocks

ALPHA 400 - DIN Wall-Mounted Distribution Boards - Delta Control

ALPHA 400 - DIN Wall-Mounted Distribution Boards - Delta Control

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ALPHA</strong> FIX <strong>Terminal</strong> <strong>Blocks</strong><br />

Insulation Displacement <strong>Terminal</strong>s<br />

8WH hybrid through-type terminals<br />

© Siemens AG 2010<br />

Version DT Order No. Price<br />

per PU<br />

Unit(s) Unit(s)<br />

Covers, for terminal size 2.5 mm²<br />

Versions<br />

• Two clamping points<br />

- Screw/insulation displacement terminals C 8WH9 000-1DA00 100 50 044<br />

- Spring-loaded/insulation displacement terminals C 8WH9 000-1CA00 100 50 044<br />

• Three clamping points<br />

- Screw/insulation displacement terminals C 8WH9 000-2DA00 100 50 044<br />

- Spring-loaded/insulation displacement terminals C 8WH9 000-2CA00 100 50 044<br />

Cover segments, for terminal size 1.5 mm² <strong>and</strong> three or four<br />

clamping points<br />

C 8WH9 001-0AA00 100 50 044<br />

PU<br />

PS*/<br />

P. unit<br />

PG<br />

8WH two-tier terminals<br />

■ Overview<br />

Key features of the insulation displacement two-tier terminals for<br />

terminal size 1.5 mm² are their compact design <strong>and</strong> double<br />

bridge slot per tier. This enables simultaneous bridging <strong>and</strong><br />

testing.<br />

With its clear <strong>and</strong> space-saving front connection arrangement,<br />

this two-tier terminal series provides additional space between<br />

the cable ducts for wiring.<br />

The PE/ground conductor terminal of this series meets all the requirements<br />

of IEC 60947-7-2.<br />

These include:<br />

• Low contact resistance,<br />

• Stainless clamping points <strong>and</strong> PE mounting foot<br />

• Green-yellow enclosure <strong>and</strong><br />

• Additional inscription options<br />

15<br />

■ Technical specifications<br />

8WH3 020-0AE00<br />

8WH3 020-0CE07<br />

8WH3 020-0AE01<br />

8WH3 020-5AE00<br />

Dimensions<br />

• Width / length / width of cover in mm 5.2 / 99.6 / 2.2<br />

• Height (TS 35/7.5 / TS 35/15) in mm 49.9 / 57.4<br />

Technical specifications acc. to IEC/DIN VDE<br />

• Max. load current in A / cross-section in mm² 17.5 / 1.5 --<br />

• Rated impulse withst<strong>and</strong> voltage in kV / pollution degree 6 / 3<br />

• Overvoltage category / insulating group<br />

III / I<br />

Conductor cross-section acc. to DIN VDE 0295<br />

• Core insulation<br />

PVC / PE (other insulation types on request)<br />

• Solid/finely str<strong>and</strong>ed H05V-U/R/K / H07V-U/R/K in mm² 0.4 ... 1.0 / 1.5<br />

• Halogen-free H05Z-U/R/K / H07Z-U/R/K in mm² 0.5 ... 1.0 / 1.5<br />

• Finely str<strong>and</strong>ed / very finely str<strong>and</strong>ed<br />

- (Str<strong>and</strong> ∅ ≥ 0.1 mm) in mm² 0.25 ... 0.34<br />

- (Str<strong>and</strong> ∅ ≥ 0.19 mm) AWG 24-16<br />

Number of circuits<br />

• At least 100-times the same cross-section in mm² 0.25 ... 1.5<br />

Insulation type<br />

PA<br />

• Flammability class acc. to UL 94<br />

V0<br />

Approval data (UL/CUL <strong>and</strong> CSA)<br />

• Rated voltage / current / cable sizes<br />

- UL/CUL: in V/A / AWG 600 / 10 / 24-16 -- / -- / 24-16<br />

- CSA: in V/A / AWG --<br />

Support rails/protective conductor busbars -- See section Support rails<br />

15/22 Siemens ET A1 · 10/2009<br />

* You can order this quantity or a multiple thereof.