© Siemens AG 2010<br />

<strong>ALPHA</strong> 8HP Molded-Plastic <strong>Distribution</strong> Systems<br />

Single Enclosures<br />

Enclosures with main <strong>and</strong><br />

EMERGENCY-STOP switches, 63 A ... 800 A<br />

■ Overview<br />

• Enclosures with integrated switch disconnectors as main <strong>and</strong><br />

EMERGENCY-STOP switch.<br />

• With integrated door-coupling rotary operating mechanism,<br />

lockable with padlocks:<br />

- Operating mechanism version A<br />

H<strong>and</strong>le: Black<br />

Display plate: Light gray<br />

- Operating mechanism version B<br />

EMERGENCY-STOP (h<strong>and</strong>le: red; display plate: yellow).<br />

• For switch disconnectors, see Catalog LV 1<br />

"Switching <strong>and</strong> Protecting with SENTRON – Switch<br />

Disconnectors"<br />

1<br />

I2_12246<br />

1<br />

2<br />

2a<br />

2b<br />

4<br />

Enclosure base part<br />

Mounting plate<br />

Switch disconnector<br />

Door-coupling rotary<br />

operating mechanism<br />

Cover, opaque<br />

2<br />

2a<br />

2b<br />

4<br />

2b<br />

Enclosure<br />

size<br />

Rated<br />

current I n<br />

Rated<br />

operational<br />

current I e<br />

Rated<br />

breaking<br />

capacity<br />

Operating<br />

mechanism<br />

Complete<br />

enclosures<br />

(supplied<br />

assembled)<br />

W x H x D Cover,<br />

deep<br />

With intermediate<br />

frames<br />

Equipment<br />

A A<br />

version<br />

Type mm mm 2<br />

2 63 63 500 A/660 V<br />

(AC-23)<br />

125 125 125 A/690 V<br />

(AC-23 A)<br />

160 160 250 A/660 V<br />

(AC-23)<br />

250 250 800 A/660 V<br />

(AC-22)<br />

400 400 2400 A/660 V<br />

(AC-23)<br />

1200 A/660 V<br />

(AC-22)<br />

3 160 160 250 A/660 V<br />

(AC-23)<br />

250 250 250 A/690 V<br />

(AC-23 A)<br />

800 A/660 V<br />

(AC-22)<br />

400 400 2400 A/660 A<br />

(AC-23)<br />

1200 A/660 V<br />

(AC-23)<br />

630 630 400 A/690 V<br />

(AC-23 B)<br />

2500 A/660 V<br />

(AC-23)<br />

1000 800 2) 2500 A/660 V<br />

(AC-23)<br />

1) An additional identical terminal can be installed for the 5th conductor.<br />

2) Full load of 800 A only possible with Cu busbars 2 × (30 mm × 10 mm)<br />

<strong>and</strong> infeed Cu 2 × (40 mm × 5 mm) or Cu cable 2 × (3 × 240) mm 2 .<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

A<br />

B<br />

Conductor<br />

connections,<br />

main conductor<br />

(PEN)<br />

8HP2 705 307 x 307 x 212 -- -- 3KA50 switch<br />

Up to 35<br />

8HP2 742 disconnectors with integrated<br />

8WA1 205 terminal<br />

for 4th conductor<br />

(Up to 35) 1)<br />

8HP2 707 307 x 307 x 147 -- -- 3KA52 switch<br />

Up to 70<br />

8HP2 747 disconnectors with integrated<br />

(Up to 70) 1)<br />

8WA1 206 termi-<br />

nal for 4th conductor<br />

8HP2 714 307 x 307 x 212 ✔ -- 3KA53 switch<br />

Up to 120<br />

8HP2 744 disconnectors with integrated<br />

(Up to 70) 1)<br />

8WA1 206 termi-<br />

nal for 4th conductor<br />

8HP2 732 307 x 307 x 212 ✔ -- 3KE42 switch<br />

Up to 150<br />

8HP2 752 disconnector with integrated<br />

(Up to 70) 1)<br />

8JK4 01 terminal<br />

for 4th conductor<br />

8HP2 716 307 x 307 x 212 ✔ -- 3KA57 switch<br />

Up to 150<br />

8HP2 746 disconnectors<br />

(Up to 70) 1)<br />

8HP2 734<br />

8HP2 754<br />

307 x 307 x 212 ✔ -- 3KE43 switch<br />

disconnectors with integrated<br />

8JK4 04 terminal<br />

for 4th conductor<br />

Up to 2 × 150<br />

or 1 × 240<br />

(Up to 1 × 150)<br />

8HP2 711 307 x 614 x 147 -- -- 3KA53 switch disconnector<br />

Up to 120<br />

8HP2 748<br />

with integrated<br />

8WA1 206 terminal<br />

(up to 70) 1)<br />

8HP2 712 307 x 614 x 239 -- ✔ 3KA55 switch disconnectors<br />

Up to 150<br />

8HP2 761<br />

(up to 70)<br />

8HP2 733 307 x 614 x 239 -- ✔ 3KE42 switch<br />

Up to 150<br />

8HP2 753 disconnector with integrated<br />

(Up to 70) 1)<br />

8JK4 01 terminal<br />

for 4th conductor<br />

8HP2 717<br />

8HP2 762<br />

8HP2 735<br />

8HP2 755<br />

8HP2 718<br />

8HP2 763<br />

8HP2 736<br />

8HP2 756<br />

8HP2 738<br />

8HP2 758<br />

307 x 614 x 239 -- ✔ 3KA57 switch<br />

disconnectors<br />

307 x 614 x 239 -- ✔ 3KE43 switch<br />

disconnectors<br />

with integrated<br />

8JK4 04 terminal for 4th<br />

conductor<br />

307 x 614 x 239 -- ✔ 3KA58 switch<br />

disconnectors<br />

307 x 614 x 239 -- ✔ 3KE44 switch<br />

disconnectors with integrated<br />

8JK4 06 terminal<br />

for 4th conductor<br />

307 x 614 x 239 -- ✔ 3KE45 switch<br />

disconnectors with integrated<br />

8JK4 06 terminal<br />

for 4th conductor<br />

Up to 150<br />

(up to 70)<br />

Up to 2 × 150<br />

or 1 × 240<br />

(Up to 240)<br />

Up to 240<br />

(up to 70)<br />

Up to 240<br />

(up to 150)<br />

Up to 2 × 240<br />

up to 240<br />

8<br />

Siemens ET A1 · 10/2009<br />