© Siemens AG 2010<br />

<strong>ALPHA</strong> FIX <strong>Terminal</strong> <strong>Blocks</strong><br />

Insulation Displacement <strong>Terminal</strong>s<br />

8WH hybrid through-type terminals<br />

■ Overview<br />

The advantages of the various connection systems are combined<br />

in the hybrid versions. The time-saving insulation displacement<br />

terminal, for example, is used in control cabinets,<br />

while the screw terminal is used for wiring to the end user.<br />

PE terminals are also available with the same contour as the<br />

through-type terminals.<br />

■ Technical specifications<br />

8WH3 100-2DE00<br />

8WH3 100-2DE01<br />

8WH3 120-2FE00<br />

8WH3 120-2FE01<br />

8WH3 103-2DE00<br />

8WH3 103-2DE01<br />

Dimensions<br />

• Width / length / width of cover in mm 5.2 / 58.8 / 2.2 5.2 / 93.5 / 22 5.2 / 76.4 / 2.2<br />

• Height (TS 35/7.5 / TS 35/15) in mm 42.8 / 50.3 55.5 / 63 42.8 / 50.3<br />

Technical specifications acc. to IEC/DIN VDE<br />

• Max. load current in A / cross-section in mm² 17.5 / 1.5<br />

• Rated impulse withst<strong>and</strong> voltage in kV / pollution degree 8 / 3<br />

• Overvoltage category / insulating group<br />

III / I<br />

Conductor cross-section acc. to DIN VDE 0295<br />

• Core insulation<br />

PVC / PE (other insulation types on request)<br />

• Solid/finely str<strong>and</strong>ed H05V-U/R/K / H07V-U/R/K in mm² 0.5 ... 1.0 / 1.5<br />

• Halogen-free H05Z-U/R/K / H07Z-U/R/K in mm² 0.5 ... 1.0 / 1.5<br />

• Finely str<strong>and</strong>ed / very finely str<strong>and</strong>ed<br />

- (Str<strong>and</strong> ∅ ≥ 0.1 mm) in mm² 0.25 ... 0.34<br />

- (Str<strong>and</strong> ∅ ≥ 0.19 mm) AWG 24-16<br />

Number of circuits<br />

• At least 100-times the same cross-section in mm² 0.25 ... 1.5<br />

Connection capacities<br />

Screw terminals<br />

• Flexible with end sleeve without/with plastic sleeve in mm² 0.25 ... 2.5 / 0.25 ... 2.5<br />

Multi-conductor connection (two conductors of same cross-section)<br />

• Rigid / flexible 0.14 ... 1.5 / 0.14 ... 1.5<br />

• Flexible with end sleeve without plastic sleeve in mm² 0.25 ... 1.5<br />

• Flexible with TWIN end sleeve with plastic sleeve in mm² 0.5 ... 1.5<br />

Stripped length 9<br />

Plug gage (IEC 60 947-1)<br />

A3<br />

Screw thread M 3<br />

Tightening torque in Nm 0.6 ... 0.8<br />

Insulation type<br />

PA<br />

• Flammability class acc. to UL 94<br />

V0<br />

Approval data (UL/CUL <strong>and</strong> CSA)<br />

• Rated voltage / current / cable sizes<br />

- UL/CUL: in V/A / AWG Applied for<br />

- CSA: in V/A / AWG Applied for<br />

15<br />

Siemens ET A1 · 10/2009<br />

15/11