8<br />

<strong>ALPHA</strong> 8HP Molded-Plastic <strong>Distribution</strong> Systems<br />

Single Enclosures<br />

Assembly kits for<br />

load break <strong>and</strong> parallel switches<br />

■ Overview<br />

Assembly kit for load break switches, 250 A to 630 A<br />

Assembly kit for parallel switches, 500 A to 1000 A<br />

Enclosure<br />

size<br />

Rated current<br />

I n<br />

Rated<br />

operational<br />

current I e<br />

■ Selection <strong>and</strong> ordering data<br />

Switch disconnector/<br />

main conductor<br />

connection<br />

© Siemens AG 2010<br />

Individual components<br />

Enclosure base<br />

parts/covers/<br />

intermediate frames<br />

Switch<br />

disconnectors<br />

Assembly kits<br />

A A Type Type<br />

4 250 250 3KE42 8HP1 104 2 × 3KE42 30-0AA With changeover contact<br />

(500) 1) (500) 1) 8HP1 204<br />

mechanism<br />

1 × 150 mm 2 2 × 8HP1 284<br />

or<br />

with shifting linkage for<br />

parallel switching<br />

400 400 3KE43 8HP1 104 2 × 3KE43 30-0AA With changeover contact<br />

(800) 1) (630) 1) 8HP1 204<br />

mechanism<br />

2 × 150 mm 2 2 × 8HP1 284<br />

or<br />

with shifting linkage for<br />

parallel switching<br />

630 630 3KE44 8HP1 104 2 × 3KE44 30-0AA With changeover contact<br />

(1260) 1) (1000) 1) 8HP1 204<br />

mechanism<br />

2 × 240 mm 2 2 × 8HP1 284<br />

or<br />

with shifting linkage for<br />

parallel switching<br />

1) Values in brackets apply to parallel switches. For thermal reasons the rated<br />

operational current is reduced to approximately 80 % of the rated current.<br />

Type<br />

8HP5 458<br />

8HP5 457<br />

8HP5 458<br />

8HP5 457<br />

8HP5 458<br />

8HP5 457<br />

Version DT Order No. Price<br />

per PU<br />

Unit(s) Unit(s)<br />

Assembly kits for load break switches <strong>and</strong> parallel switches<br />

Versions<br />

• Enclosure base parts A 8HP1 104 1 1 046<br />

• Covers A 8HP1 204 1 1 046<br />

• Intermediate frames A 8HP1 284 1 1 046<br />

• Switch disconnectors<br />

- 250 A (500 A) 1 ) B 3KE42 30-0AA 1 1 103<br />

- 400 A (800 A) 1) B 3KE43 30-0AA 1 1 103<br />

- 630 A (1260 A) 1) B 3KE44 30-0AA 1 1 103<br />

• Assembly kits<br />

- With changeover contact mechanism 2) A 8HP5 458 1 1 046<br />

- With shifting linkage for parallel switching A 8HP5 457 1 1 046<br />

Note<br />

• The assembly kit must be ordered as individual components (enclosure base,<br />

covers, 2 x intermediate frames, 2 x 3KE switch disconnectors <strong>and</strong> required<br />

assembly kit).<br />

• The switches must be connected using copper busbars or NYA cables.<br />

• The "break-before-make" version of the changeover contact is supplied.<br />

Footnote<br />

1) Values in brackets apply to parallel switches. For thermal reasons the rated<br />

operational current is reduced to approximately 80 % of the rated current.<br />

2) The "break-before-make" version of the changeover contact is supplied. If<br />

the "make-before-break" version is required, a "-Z" must be added to the<br />

Order No. <strong>and</strong> "make-before-break" specified in plain text.<br />

For accessories, see page 8/27 ff.<br />

PU<br />

PS*/<br />

P. unit<br />

PG<br />

8/24 Siemens ET A1 · 10/2009<br />

* You can order this quantity or a multiple thereof.