<strong>ALPHA</strong> 8HP Molded-Plastic <strong>Distribution</strong> Systems<br />

Accessories<br />

Components for busbar systems<br />

© Siemens AG 2010<br />

8<br />

3NP42 75-1CG01<br />

Version DT Order No. Price<br />

per PU<br />

Fuse switch disconnectors,<br />

for NH1 3NP4 2 fuse links 1)<br />

A 3NP42 75-1CG01 1 1 103<br />

• For busbar mounting<br />

• Enclosures <strong>and</strong> busbars not included in delivery<br />

• Cannot be used as an individual enclosure<br />

• For mounting dimensions, see page 8/54.<br />

• Enclosure size 2<br />

• Rated current I n : 250 A<br />

• Rated operational current I e : 225 A<br />

• Connection up to 150 mm 2<br />

•Busbars<br />

- Cu 12 × 5 2) or Cu 12 × 10 with 8HP1 701 busbar supports 3) with<br />

40-mm busbar center-to-center clearance or<br />

- 8HP1 790 <strong>and</strong> 8HP1 791 busbar assembly kits<br />

• Connection over cable lug top (M10) <strong>and</strong> bottom (M10) 4)<br />

Footnote<br />

1) Raised cover or intermediate frame required.<br />

2) When using Cu 12 × 5 mm, a 3NY7 381 bar thickness compensation<br />

must be used (1 set = 5 components).<br />

3) For 8HP1 70 busbar supports see page 8/27.<br />

4) If mounting on 5-mm busbars, an additional 3NY7 381 busbar<br />

thickness compensator is required.<br />

Covers for "Fuse switch disconnectors, for NH1 3NP4 2 fuse links"<br />

Versions<br />

•Sealable A 8HP6 427 1 1 046<br />

• Not sealable A 8HP6 437 1 1 046<br />

Fuse switch disconnectors,<br />

for NH00 / 2x NH00 / NH1 fuse links from A. Jung, Ostrach 1)<br />

• For busbar mounting<br />

• Enclosures <strong>and</strong> busbars not included in delivery<br />

• Cannot be used as an individual enclosure<br />

• For mounting dimensions, see page 8/54.<br />

• Enclosure size 2<br />

• Rated current I n :<br />

- 160 A for 8HP4 310 <strong>and</strong> 8HP4 311<br />

- 250 A at 8HP4 314<br />

• Rated operational current I e :<br />

- 145 A for 8HP4 310 <strong>and</strong> 8HP4 311<br />

- 225 A at 8HP4 314<br />

• Connection:<br />

- Up to 50 mm 2 for 8HP4 310 <strong>and</strong> 8HP4 311<br />

- Up to 120 mm 2 for 8HP4 314<br />

• Busbars: Cu 20 × 8 or 2 × Cu (20 × 8), with 8HP1 704 busbar support 2)<br />

with 49-mm busbar center-to-center clearance<br />

Versions<br />

• NH00 (DTL 160 TSW), incl. 8HP6 411 covers, with clamp connections, A 8HP4 310 1 1 046<br />

top (can be switched to bottom)<br />

• 2x NH00 (DTL 160 TSW), incl. 8HP6 412 covers, with clamp connections,<br />

A 8HP4 311 1 1 046<br />

top (can be switched to bottom)<br />

• NH1 (DTL 250 TSW), incl. 8HP6 413 covers, cable lug connections, top A 8HP4 314 1 1 046<br />

M10 (can be switched to bottom) 2)<br />

Footnote<br />

Raised cover or intermediate frame required.<br />

2) For 8HP1 70 busbar supports see page 8/27.<br />