29.09.2015 Views

ALPHA Distribution Boards and Terminal Blocks

ALPHA 400 - DIN Wall-Mounted Distribution Boards - Delta Control

ALPHA 400 - DIN Wall-Mounted Distribution Boards - Delta Control

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ALPHA</strong> FIX <strong>Terminal</strong> <strong>Blocks</strong><br />

Plug-In <strong>Terminal</strong>s<br />

8WH through-type terminals<br />

© Siemens AG 2010<br />

■ Overview<br />

All types of conductors can be used with the 8WH4 plug-in<br />

terminals.<br />

Rigid conductors <strong>and</strong> crimped flexible conductors are plugged<br />

directly into the terminal.<br />

Flexible, untreated conductors can be connected using a screwdriver.<br />

These terminals can be used interconnected with the neutral<br />

busbar 10 × 3 mm.<br />

■ Technical specifications<br />

8WH4 000-0AF00<br />

8WH4 000-0AF01<br />

8WH4 000-0CF07<br />

8WH4 000-0AG00<br />

8WH4 000-0AG01<br />

8WH4 000-0CG07<br />

Dimensions<br />

• Width / length / width of cover in mm 5.2 / 59.5 / 2.2 5.2 / 59.5 / 2.2 6.2 / 66 / 2.2 6.2 / 66 / 2.2<br />

• Height (TS 35/7.5 / TS 35/15) in mm 43 / 50.5 43 / 50.5 43 / 50.5 43 / 50.5<br />

Technical specifications acc. to IEC/DIN VDE<br />

• Max. load current in A / cross-section in mm² 24 / 4 -- / 4 32 / 6 -- / 6<br />

Connection capacities<br />

• Flexible with end sleeve with plastic sleeve in mm² 0.25 ... 2.5 0.25 ... 2.5 0.25 ... 2.5 0.25 ... 2.5<br />

• Flexible with end sleeve without plastic sleeve in mm² 0.25 ... 2.5 0.25 ... 2.5 0.25 ... 2.5 0.25 ... 2.5<br />

Stripped length in mm 10 10 10 10<br />

Insulation type PA PA PA PA<br />

• Flammability class acc. to UL 94 V0 V0 V0 V0<br />

Support rails/protective conductor busbars -- See section<br />

Support rails<br />

-- See section<br />

Support rails<br />

13<br />

8WH4 000-0AH00<br />

8WH4 000-0CH07<br />

8WH4 000-0AH01<br />

Dimensions<br />

• Width / length / width of cover in mm 8.2 / 66 / 2.2 8.2 / 66 / 2.2<br />

• Height (TS 35/7.5 / TS 35/15) in mm 50 / 57.5 50 / 57.5<br />

Technical specifications acc. to IEC/DIN VDE<br />

• Max. load current in A / cross-section in mm² 41 / 10<br />

51 at 10 mm 2 conductor cross-section<br />

-- / 10<br />

51 at 10 mm 2 conductor cross-section<br />

Connection capacities<br />

• Flexible with end sleeve with plastic sleeve in mm² 0.5 ... 6 0.5 ... 6<br />

• Flexible with end sleeve without plastic sleeve in mm² 0.5 ... 8 0.5 ... 6<br />

Stripped length in mm 12 12<br />

Insulation type PA PA<br />

• Flammability class acc. to UL 94 V0 V0<br />

Support rails/protective conductor busbars -- See section Support rails<br />

13/4 Siemens ET A1 · 10/2009