© Siemens AG 2010<br />

<strong>ALPHA</strong> FIX <strong>Terminal</strong> <strong>Blocks</strong><br />

Combination Plug-In <strong>Terminal</strong>s<br />

8WH5 hybrid through-type terminals<br />

8WH5 103-3LF07 8WH5 104-3MF07 8WH5 100-2KG00 8WH5 100-3KG07<br />

8WH5 100-2KG01<br />

Dimensions<br />

• Width / length / width of cover in mm 5.2 / 60.5 / 2.2 5.2 / 81 / 2.2 6.2 / 55.9 / 2.2<br />

• Height (TS 35/7.5 / TS 35/15) in mm 36.5 / 44<br />

Technical specifications acc. to IEC/DIN VDE<br />

• Max. load current in A 1) / cross-section in mm² -- 32 / 6 --<br />

• Rated impulse withst<strong>and</strong> voltage in kV / pollution degree 6 / 3<br />

• Overvoltage category / insulating group<br />

III / I<br />

Connection capacities<br />

• Flexible with end sleeve with plastic sleeve in mm² 0.25 ... 2.5 0.25 ... 4<br />

• Flexible with end sleeve without plastic sleeve in mm² 0.25 ... 2.5 0.25 ... 4<br />

• Flexible with two-wire connection end sleeve with plastic sleeve in mm² 0.5 0.5 ... 1<br />

Stripped length 10<br />

Plug gage (IEC 60 947-1) A3 A4<br />

Insulation type<br />

PA<br />

• Flammability class acc. to UL 94<br />

V0<br />

Approval data (UL/CUL <strong>and</strong> CSA)<br />

• Rated voltage / current / cable sizes<br />

- UL/CUL: in V/A / AWG -- / -- / 26-12 Applied for<br />

- CSA: in V/A / AWG -- Applied for<br />

Support rails/protective conductor busbars See section Support rails -- See section<br />

Support rails<br />

1) Derating of the load current is necessary for higher temperatures <strong>and</strong>/or multi-pole combination plug versions.<br />

30<br />

35<br />

Maximum load current in A<br />

25<br />

20<br />

15<br />

10<br />

10-pole<br />

15-pole<br />

2-pole<br />

5-pole<br />

Maximum load current in A<br />

30<br />

25<br />

20<br />

15<br />

10<br />

10-pole<br />

15-pole<br />

2-pole<br />

5-pole<br />

5<br />

0<br />

20 40 60 80 100 120<br />

Ambient temperature in °C<br />

I2_13471<br />

5<br />

0<br />

20 40 60 80 100 120<br />

Ambient temperature in °C<br />

I2_13475<br />

Derating curve for 8WH5 100-2KF00 <strong>and</strong> 8WH5 103-2LF00<br />

Derating curve for 8WH5 100-2KG00<br />

30<br />

Maximum load current in A<br />

25<br />

20<br />

15<br />

10<br />

10-pole<br />

15-pole<br />

2-pole<br />

5-pole<br />

14<br />

5<br />

0<br />

20 40 60 80 100 120<br />

Ambient temperature in °C<br />

Derating curve for 8WH5 104-2MF00<br />

I2_13472<br />

Siemens ET A1 · 10/2009<br />

14/9