<strong>ALPHA</strong> 8HP Molded-Plastic <strong>Distribution</strong> Systems<br />

Accessories<br />

Accessories for enclosures<br />

■ Selection <strong>and</strong> ordering data<br />

© Siemens AG 2010<br />

8HP1 541<br />

Version DT Order No. Price<br />

per PU<br />

Sealing frames<br />

Versions<br />

PU<br />

Unit(s)<br />

PS*/<br />

P. unit<br />

Unit(s)<br />

• Including locking screws <strong>and</strong> nuts A 8HP1 541 1 1 046<br />

• Including locking screws <strong>and</strong> nuts,<br />

A 8HP1 542 1 1 046<br />

can be used on the narrow side of size 1 enclosures<br />

PG<br />

& 0 2 # "<br />

8<br />

8HP1 542<br />

8HP1 500<br />

8HP1 511-1<br />

& 0 2 # " <br />

5 - ' '<br />

When enclosures are connected<br />

to each other, one sealing<br />

frame is required between<br />

each set of flange openings.<br />

End cover plates<br />

• Cover plates including fixing screws <strong>and</strong> seals<br />

• If enclosure knockouts do not meet requirements, you can use the following<br />

end cover plates, with or without knockouts<br />

Versions<br />

• Without knockouts A 8HP1 500 1 1 046<br />

• With knockouts<br />

- 2 × M20 <strong>and</strong> 3 × M20/M25 <strong>and</strong> 4 × M25/M40/8HP1 80. } 8HP1 511-1 1 1 046<br />

- 6 × M25/M32 <strong>and</strong> 2 × M25/M32/M40/8HP1 80. } 8HP1 512-1 1 1 046<br />

- 2 × M20 <strong>and</strong> 8 × M25/M32 } 8HP1 513-1 1 1 046<br />

8HP1 512-1<br />

8HP1 513-1<br />

8HP1 806<br />

8HE8 541<br />

Rubber cable entries<br />

• For inserting in ∅ 38 mm knockouts to Pg 29<br />

• Can also be used as blanking plug<br />

Versions<br />

• For 1 cable with ∅ 12 ... 29 mm A 8HP1 805 1 1 046<br />

• For 2 cables with ∅ 6 ... 15 mm A 8HP1 806 1 1 046<br />

• For 3 cables with ∅ 4 ... 12.5 mm A 8HP1 807 1 1 046<br />

• For 4 cables with ∅ 4 ... 12 mm A 8HP1 808 1 1 046<br />

Breathers, PG 16 1) A 8HE8 541 1 1 046<br />

• In the case of distribution boards used in an external environment - outside<br />

or in rooms with extreme temperature fluctuations - the breathers must be<br />

installed as low as possible on the underneath of the distribution board in<br />

order to prevent condensation water forming<br />

• Degree of protection, IP54<br />

Footnote<br />

For conversion from PG to metric screw connections see General data/<br />

Application.<br />

8/34 Siemens ET A1 · 10/2009<br />

* You can order this quantity or a multiple thereof.