Dimensional Tolerances<br />

10.5.2.1 Allowable maximum out-of-plumbness (top of shell relative<br />

to shell bottom) shall not exceed 1/100 of total tank height, with a maximum of<br />

5" this dimension also applies to roof columns.<br />

10.5.3 Roundness<br />

See values and measurement locations on Table 10-2.<br />

10.5.4 Peaking<br />

Shall not exceed 0.50".<br />

10.5.5 Banding<br />

Shall not exceed 1.00".<br />

NOTE: Somewhat more lax than <strong>API</strong>-650.<br />

10.5.6 Foundations<br />

Same specifications as listed under <strong>API</strong>-650.<br />