6.3.3.3 Internal tank shell inspection (out-of-service condition) can be<br />

substituted for a program of external UT measurements made during inservice<br />

condition.<br />

6.3.4.1 Cathodic Protection System -- Survey in accordance with <strong>API</strong> RP 651.<br />