12.1.3 Repaired Weld Flaws<br />

12.1.3.1 Cavities from gouging or grinding to remove weld defects shall be<br />

either a magnetic particle or liquid penetrate tested.<br />

12.1.3.2 Completed repair of butt welds shall be examined over their full<br />

length by UT or radiographic methods.<br />

12.1.4 Temporary and Permanent Attachments to Shell Plates<br />

12.1.4.1 A ground area resulting from the removal of attachments requires a<br />

visual test.<br />

12.1.4.2 Completed welds on permanent attachments shall be examined by<br />

MT or PT, groups IV-VI, excluding the shell to bottom weld.<br />

12.1.5 Shell-to-Shell Plate Welds<br />

New welds attaching shell plate to shell plate require visual and radiographic<br />

examination. Additionally, plate greater than 1", the back-gouged surface of<br />

root pass and final pass (each side) shall be examined over its full length by a<br />

magnetic particle or liquid penetrate test.<br />

12.1.5.2 New welds on new shell plate to new shell plate are to be examined<br />

and radiographed to <strong>API</strong> 650.<br />