14.02.2017 Views

Department of Defense INSTRUCTION

x9tnk

x9tnk

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DoDI 5000.02, January 7, 2015<br />

(b) For integrated test results to count for operational testing, the lead OTA must<br />

develop a plan for the integrated test to be approved by DOT&E before the start <strong>of</strong> testing that, at<br />

a minimum, details the required test realism and conditions, operational test objectives,<br />

operational test metrics and data collection requirements. Data collected outside an approved<br />

OTP or major LFTP can be used for a DOT&E operational or live fire evaluation if the data is<br />

approved by DOT&E. Depending on circumstances, DOT&E approval will not necessarily be<br />

possible in the TEMP and may require some other documentation. Data approval will be based<br />

on understanding <strong>of</strong> the realism <strong>of</strong> the test scenario(s) used and the pedigree (test conditions and<br />

methodologies) <strong>of</strong> the data. The data in question will typically come from operational exercises,<br />

certification events, and developmental test events conducted in operationally relevant<br />

environments. Data approval should be coordinated with the LTO and DOT&E prior to the start<br />

<strong>of</strong> testing. When advance coordination is not possible, the LTO will facilitate data re-use (in a<br />

DOT&E assessment or evaluation) through independent documentation <strong>of</strong> the test data pedigree<br />

(test conditions and methodologies).<br />

(5) In OT&E, typical users or units will operate and maintain the system or item under<br />

conditions simulating combat stress in accordance with 10 U.S.C. 139 (Reference (g) (h)) and<br />

peacetime conditions, when applicable. The lead OTA, in consultation with the user and the<br />

Program Manager, will identify realistic operational scenarios based on the CONOPS (per<br />

paragraph 5d(1) in this enclosure) and mission threads derived from the Joint Mission Essential<br />

Task List or DoD Component-specific Mission Essential Task List. See paragraph 7d <strong>of</strong> this<br />

enclosure for risk-assessed OT&E <strong>of</strong> s<strong>of</strong>tware acquisitions.<br />

(6) In accordance with 10 U.S.C. 2399 (Reference (g) (h)), persons employed by the<br />

contractor for the system being developed may only participate in OT&E <strong>of</strong> systems on under<br />

OSD OT&E oversight to the extent they are planned to be involved in the operation,<br />

maintenance, and other support <strong>of</strong> the system when deployed in combat.<br />

(a) A contractor that has participated (or is participating) in the development,<br />

production, or testing <strong>of</strong> a system for a DoD Component (or for another contractor <strong>of</strong> the DoD)<br />

may not be involved in any way in establishing criteria for data collection, performance<br />

assessment, or evaluation activities for OT&E.<br />

(b) These limitations do not apply to a contractor that has participated in such<br />

development, production, or testing, solely in test or test support on behalf <strong>of</strong> the DoD.<br />

(7) IOT&E for all programs will use production or production-representative test articles<br />

that, at a minimum, will incorporate the same parts and s<strong>of</strong>tware items to be used in LRIP<br />

articles. Production-representative systems meet the following criteria:<br />

(a) The hardware and s<strong>of</strong>tware must be as defined by the system-level critical design<br />

review, functional configuration audit, and system verification review, including correction <strong>of</strong><br />

appropriate major deficiencies identified during prior testing.<br />

Change 2, 02/02/2017 121<br />