28.12.2012 Views

SUNNY WEBBOX - User Manual - SMA Solar Technology AG

SUNNY WEBBOX - User Manual - SMA Solar Technology AG

SUNNY WEBBOX - User Manual - SMA Solar Technology AG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SMA</strong> <strong>Solar</strong> <strong>Technology</strong> <strong>AG</strong> Commissioning<br />

6.8.2 Connecting the Sunny WebBox to the RS485 Communication<br />

Bus<br />

This section describes how to connect the Sunny WebBox to the RS485 communication bus. It will be<br />

assumed that the Sunny WebBox is located at the end of the RS485 communication bus.<br />

RS485 cabling and pin assignment in the system<br />

See the RS485 cabling plan poster for the system cabling and pin assignment.<br />

1. Connect cables to the RS485 bus nodes as described in the bus node manual.<br />

2. Remove 40 cm from the cable sleeve of the RS485<br />

communication cable on the side of the Sunny<br />

WebBox.<br />

3. Remove shielding until flush with cable sleeve.<br />

4. Strip approx. 6 mm of insulation from the ends of the conductors.<br />

Connect the insulated conductors of the cable to the plug connector correctly<br />

Note the color of the insulated conductors of the communication cable.<br />

2 | D+ ________________________<br />

5 | GND ________________________<br />

7 | D- ________________________<br />

<strong>User</strong> <strong>Manual</strong> SWebBox-BEN111033 37