8.8<br />

ENGLISH<br />

Troubleshooting <strong>ED</strong> 1,3 M – <strong>ED</strong> 3 M – <strong>ED</strong> 3 M <strong>HS</strong><br />

FAULTS CHECK (POSSIBLE CAUSES) REM<strong>ED</strong>Y<br />

1. The motor is not A. The magnetothermal switch of the panel A. Check the insulation of the pump cables, of the<br />

fed.<br />

(ref.4) or the differential automatic switch on pump or of the floats. Reset the magnetothermal<br />

the distribution panel has tripped.<br />

switch located in the panel (rif.QM1) or the<br />

differential switch on the distribution panel.<br />

B. Check the control unit connecting cables and any<br />

B. No voltage on terminals L1-N<br />

switches or insulating switches in the system.<br />

C. Turn off the main switch for three minutes, then<br />

switch it on again Starting of the electropump<br />

C. The protection of the internal transformer has excludes the fault. If the electropump is not fed,<br />

tripped.<br />

or is temporarily fed, identify any short circuits<br />

in the secondary circuit of the transformer.<br />

D. The supply voltage is insufficient.<br />

2. The protection<br />

ref. QM1<br />

intervenes.<br />

3. The thermal<br />

protection in the<br />

windings of the<br />

motor trips.<br />

4. The pump<br />

continues<br />

delivering and<br />

does not respond<br />

to external<br />

commands.<br />

5. The remote<br />

control switch<br />

ref. KM1 is fed<br />

intermittently<br />

6. The remote<br />

alarm is not<br />

working.<br />

8.9 List of spare parts<br />

<strong>ED</strong> 1,3 M<br />

D. The remote control switch ref. KM1 vibrates.<br />

A. Pump impeller blocked.<br />

B. The timer for regulating strong static<br />

torque time is set over 4 seconds (only<br />

for <strong>ED</strong>3 M<strong>HS</strong> )<br />

A. Check the working environment temperature<br />

of the electropump.<br />

B. Pump impeller blocked or clogged<br />

C. Check the state of the rotor shaft bearings of<br />

the electropump.<br />

A. The floats are not correctly connected to the<br />

control panel.<br />

B. The floats are faulty.<br />

C. The remote control switch KM1 is faulty<br />

(contacts are stuck).<br />

A. The connections of the leads from the motor<br />

are inverted on the control unit terminals.<br />

(only for <strong>ED</strong> 3 M, <strong>ED</strong> 3 M<strong>HS</strong>)<br />

A. The reference float P is not connected exactly<br />

to the control unit or does not follow the<br />

water level.<br />

B. The float is faulty.<br />

C. The acoustic or luminous signal ref.Q is not<br />

correctly connected to the respective<br />

terminals.<br />

27<br />

A. Carry out maintenance to free the impeller.<br />

B. Set the timer correctly as indicated in ref. KT1<br />

A. Reduce the temperature of the fluid to be<br />

pumped.<br />

B. Carry out maintenance to free the impeller.<br />

C. Change the pump bearings if worn.<br />

A. Correctly connect the floats and check operation<br />

of the system (par.8.3)<br />

B. Change the floats.<br />

C. Change the part.<br />

A. Connect the leads from the motor, strictly<br />

respecting the enclosed diagrams.<br />

A. Correctly connect the float and check operation<br />

of the system.<br />

B. Change the float.<br />

C. Check the connections and the correspondence<br />

of the electrical characteristics.<br />

REF Code Description Model<br />

QM1 002740051 MODULAR AUTOMATIC SWITCH<br />

1P+N 10A<br />

KM1<br />

002773460<br />

19133 MERLIN GERIN<br />

EF 681 0 ABB<br />

LN C10 SIEI<br />

REMOTE CONTROL SWITCH 4KW 400V AC3 24V 50/60Hz LC1D09B7 TELEMECANIQUE<br />

100-C09KJ10 AB<br />

A 09-30-10 ABB<br />

TC1 002771290 SINGLE-PHASE TRANSFORMER 0-230/24 30VA<br />

KA1 002773261 BAYONET RELAY, 2 CONTACTS, COIL 24V ac 40.52.80.24.0000 FINDER<br />

<strong>ED</strong> 3 M<br />

REF Code Description Model<br />

QM1 002740052 MODULAR AUTOMATIC SWITCH<br />

1P+N 16A<br />

KM1<br />

19135 MERLIN GERIN<br />

EF 682 8 ABB<br />

LNC 16 SIEI<br />

002773462 REMOTE CONTROL SWITCH 5.5KW 400V AC3 24V 50/60Hz LC1 D121B7 TELEMECANIQUE<br />

100-C12KJ10 AB<br />

A 12-30-10 ABB<br />

TC1 002771290 SINGLE-PHASE TRANSFORMER 0-230/24 30VA<br />

KA1 002773261 BAYONET RELAY, 2 CONTACTS, COIL 24V ac 40.52.80.24.0000 FINDER<br />

<strong>ED</strong> 3 M <strong>HS</strong><br />

REF Code Description Model<br />

QM1 002740052<br />

MODULAR AUTOMATIC SWITCH<br />

1P+N 16A<br />

19135 MERLIN GERIN<br />

EF 682 8 ABB<br />

LNC 16 SIEI<br />

KM1<br />

002773462 REMOTE CONTROL SWITCH 5.5KW 400V AC3 24V 50/60Hz<br />

LC1 D12B7 TELEMECANIQUE<br />

100-C12KJ10 AB<br />

A 12-30-10 ABB<br />

TC1 002771290 SINGLE-PHASE TRANSFORMER 0-230/24 30VA<br />

KA1 002773261 BAYONET RELAY, 2 CONTACTS, COIL 24V ac 40.52.80.24.0000 FINDER<br />

KT1 002773244 TIM<strong>ED</strong> BAYONET RELAY 24V ac 86.10.0.024.0000 FINDER