ED 3 M HS - DAB Pumps S.p.a.
ED 3 M HS - DAB Pumps S.p.a.
ED 3 M HS - DAB Pumps S.p.a.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
9.8<br />
ENGLISH<br />
Troubleshooting <strong>ED</strong> 1 T-<strong>ED</strong> 1,5 T-<strong>ED</strong> 2,5 T-<strong>ED</strong> 4 T-<strong>ED</strong> 7,5 T-<strong>ED</strong> 8 T- <strong>ED</strong> 15 T SD<br />
<strong>ED</strong> 20 T SD-<strong>ED</strong> 25 T SD-<strong>ED</strong> 30 T SD<br />
FAULTS CHECK (POSSIBLE CAUSES) REM<strong>ED</strong>Y<br />
1. The motor is not A. The magnetothermal switch of the panel A. Check the insulation of the pump cables, of<br />
fed<br />
(ref.4) or the differential automatic switch on the pump or of the floats. Reset the<br />
the distribution panel has tripped..<br />
magnetothermal switch located in the panel<br />
(rif.QM1) or the differential switch on the<br />
distribution panel.<br />
B. No voltage on terminals L1-L2-L3<br />
B. Check the control unit connecting cables and<br />
any switches or insulating switches in the<br />
system.<br />
C. The protection of the internal transformer has C. Turn off the main switch for three minutes,<br />
tripped.<br />
then switch it on again Starting of the<br />
electropump excludes the fault. If the<br />
D. The remote control switch ref. KM1 vibrates. D.<br />
electropump is not fed, or is temporarily fed,<br />
identify any short circuits in the secondary<br />
circuit of the transformer.<br />
The supply voltage is insufficient.<br />
2. The protection ref. A.<br />
QM1 intervenes..<br />
Pump impeller blocked.<br />
A. Carry out maintenance to free the impeller.<br />
FAULTS CHECK (POSSIBLE CAUSES) REM<strong>ED</strong>Y<br />
3. The thermal A. Check the working environment temperature A. Reduce the temperature of the fluid to be<br />
protection in the of the electropump.<br />
pumped.<br />
windings of the B. Pump impeller blocked or clogged.<br />
B. Carry out maintenance to free the impeller.<br />
motor trips. C. Check the state of the rotor shaft bearings of C.<br />
the electropump.<br />
Change the pump bearings if worn.<br />
4. The pump A. The floats are not correctly connected to the A. Correctly connect the floats and check<br />
continues<br />
control panel.<br />
operation of the system (par.8.3)<br />
delivering and B. The floats are faulty.<br />
B. Change the floats.<br />
does not respond C. The remote control switch KM1 is faulty C. Change the part<br />
to external (contacts are stuck).<br />
5.<br />
commands.<br />
The remote control A. The connections of the leads from the motor A. Connect the leads from the motor, strictly<br />
switch ref. KM1 is are inverted on the control unit terminals. respecting the enclosed diagrams.<br />
fed intermittently Only for <strong>ED</strong> 2,5 T<br />
6. The remote alarm A. The reference float P is not connected exactly A. Correctly connect the float and check<br />
is not working. to the control unit or does not follow the water<br />
level..<br />
operation of the system..<br />
B. The float is faulty.<br />
B. Change the float.<br />
C. The acoustic or luminous signal ref.Q is not C. Check the connections and the<br />
correctly connected to the respective terminals correspondence<br />
characteristics.<br />
of the electrical<br />
9.9 List of spare parts<br />
<strong>ED</strong> 1 T<br />
REF Code Description Model<br />
QM1 002773350 MODULAR AUTOMATIC SWITCH 1,6/2,5A<br />
GV2-ME07 TELEMECANIQUE<br />
140-MN-0250 AB<br />
MS325/2.5 ABB<br />
KM1 002773460 REMOTE CONTROL SWITCH 4 KW 400V AC3 24V 50/60Hz<br />
LC1 D09 B7 TELEMECANIQUE<br />
100-C09KJ10 AB<br />
A 9-30-10 ABB<br />
TC1 002771291 SINGLE-PHASE TRANSFORMER 0-230-400/24 30VA<br />
KA1 002773261 BAYONET RELAY, 2 CONTACTS, COIL 24V ac 40.52.80.24.0000 FINDER<br />
<strong>ED</strong> 1,5 T<br />
REF Code Description Model<br />
QM1 002773351 MAGNETOTHERMAL SWITCH 2.5/4A<br />
KM1 002773460 REMOTE CONTROL SWITCH 4 KW 400V AC3 24V 50/60Hz<br />
TC1 002771291 SINGLE-PHASE TRANSFORMER 0-230-400/24 30VA<br />
31<br />
GV2-ME08 TELEMECANIQUE<br />
140-MN-0400 AB<br />
MS325/4 ABB<br />
LC1 D09B7 TELEMECANIQUE<br />
100-C09KJ10 AB<br />
A 9-30-10 ABB<br />
KA1 002773261 BAYONET RELAY, 2 CONTACTS, COIL 24V ac 40.52.80.24.0000 FINDER